5 V flyback with high secondary current

A low-voltage output makes secondary winding and rectifier current central to a 25 W design.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
13.28 : 1
Primary Lₘ
969.6 µH
Drain Vₚₖ
474.7 V
Clamp loss
0.2807 W
Flyback drain voltage Flyback drain voltage High line · 13.9 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak475 VPlateau397 VClamp loss0.281 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating474.7 V / 650 V

Reflected voltage / duty limit72 V / 82.5 V

Result breakdown
Primary : secondary turns13.2841 : 1
Primary magnetizing inductance969.583 µH
Low-line duty40.678 %
Maximum reflected voltage at duty limit82.5 V
Primary peak across line range1.01972 A
Worst primary RMS0.468987 A
Primary RMS at low line0.468987 A
Primary RMS at high line0.243509 A
Secondary peak across line range13.5461 A
Worst secondary RMS7.52354 A
Secondary RMS at low line7.52354 A
Secondary RMS at high line6.87263 A
High-line conduction modeCCM
Estimated high-line drain peak474.65 V
Drain voltage headroom175.35 V
RCD clamp dissipation0.280651 W
Clamp resistance75,952 Ω
Clamp capacitance3.65728 nF
Clamp ripple budget7.3 V
Estimated total converter loss budget5.4878 W

Worked calculation

Np/Ns = 72 V / (5 V + 0.42 V) = 13.2841 : 1

Read low- and high-line secondary RMS separately. Compare them with the secondary peak before selecting winding wire and a rectifier.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.