48 V bus to isolated 12 V bias

An isolated bias supply must work across a 36–75 V telecom bus.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
2.097 : 1
Primary Lₘ
104.9 µH
Drain Vₚₖ
131.4 V
Clamp loss
0.5564 W
Flyback drain voltage Flyback drain voltage High line · 7.14 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak131 VPlateau101 VClamp loss0.556 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating131.4 V / 150 V

Reflected voltage / duty limit26 V / 36 V

Result breakdown
Primary : secondary turns2.09677 : 1
Primary magnetizing inductance104.912 µH
Low-line duty41.9355 %
Maximum reflected voltage at duty limit36 V
Primary peak across line range1.86882 A
Worst primary RMS0.898191 A
Primary RMS at low line0.898191 A
Primary RMS at high line0.570969 A
Secondary peak across line range3.9185 A
Worst secondary RMS2.21608 A
Secondary RMS at low line2.21608 A
Secondary RMS at high line2.03333 A
High-line conduction modeCCM
Estimated high-line drain peak131.375 V
Drain voltage headroom18.625 V
RCD clamp dissipation0.55639 W
Clamp resistance5,436.83 Ω
Clamp capacitance26.2758 nF
Clamp ripple budget2.75 V
Estimated total converter loss budget2.45455 W

Worked calculation

Np/Ns = 26 V / (12 V + 0.4 V) = 2.09677 : 1

Lower the clamp setting slightly and compare the gain in drain headroom with the increase in clamp loss.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.