Clamp capacitor ripple for an 8 W flyback

An auxiliary converter needs a small clamp-voltage variation across each switching period.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
6.04 : 1
Primary Lₘ
1,693 µH
Drain Vₚₖ
506.5 V
Clamp loss
0.09327 W
Flyback drain voltage Flyback drain voltage High line · 10.5 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak506 VPlateau423 VClamp loss0.0933 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain headroom available

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating506.5 V / 650 V

Reflected voltage / duty limit63 V / 76.44 V

Result breakdown
Primary : secondary turns6.04027 : 1
Primary magnetizing inductance1,693.24 µH
Low-line duty36.4162 %
Maximum reflected voltage at duty limit76.4407 V
Primary peak across line range0.377312 A
Worst primary RMS0.158602 A
Primary RMS at low line0.158602 A
Primary RMS at high line0.0818027 A
Secondary peak across line range2.27907 A
Worst secondary RMS1.26588 A
Secondary RMS at low line1.26588 A
Secondary RMS at high line1.18115 A
High-line conduction modeCCM
Estimated high-line drain peak506.45 V
Drain voltage headroom143.55 V
RCD clamp dissipation0.0932705 W
Clamp resistance225,420 Ω
Clamp capacitance2.33483 nF
Clamp ripple budget2.9 V
Estimated total converter loss budget2.12658 W

Worked calculation

Np/Ns = 63 V / (10 V + 0.43 V) = 6.04027 : 1

Compare clamp capacitance for 2% and 5% ripple. The modeled resistor dissipation is unchanged by this ripple budget.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.