24 V flyback with a tight drain rating

A candidate 500 V MOSFET is being screened for a 60 W flyback at high line.

Design inputs

Input & output
Transformer & clamp

Low-line primary ripple divided by primary peak.

View live readout ↑

Live readout

Edit inputs
Turns Nₚ:Nₛ
3.455 : 1
Primary Lₘ
403.5 µH
Drain Vₚₖ
531.7 V
Clamp loss
1.41 W
Flyback drain voltage Flyback drain voltage High line · 10 µs Vᴅₛ Vin Drain RCD Np : Ns Drain peak532 VPlateau465 VClamp loss1.41 W
The ringing sketch shows the clamp and reflected plateaus. Ring frequency and residual overshoot depend on the physical circuit.
Drain rating exceeded

Drain stress includes the clamp setting at high line. Check overshoot on the bench.

Drain stress / rating531.7 V / 500 V

Reflected voltage / duty limit85 V / 92.31 V

Result breakdown
Primary : secondary turns3.45528 : 1
Primary magnetizing inductance403.495 µH
Low-line duty45.9459 %
Maximum reflected voltage at duty limit92.3077 V
Primary peak across line range2.07036 A
Worst primary RMS1.04155 A
Primary RMS at low line1.04155 A
Primary RMS at high line0.474695 A
Secondary peak across line range7.1537 A
Worst secondary RMS3.90351 A
Secondary RMS at low line3.90351 A
Secondary RMS at high line3.46801 A
High-line conduction modeCCM
Estimated high-line drain peak531.7 V
Drain voltage headroom-31.7 V
RCD clamp dissipation1.40975 W
Clamp resistance15,537.5 Ω
Clamp capacitance12.8721 nF
Clamp ripple budget7.4 V
Estimated total converter loss budget8.96552 W

Worked calculation

Np/Ns = 85 V / (24 V + 0.6 V) = 3.45528 : 1

The drain stress exceeds the device rating. Compare a higher-rated device before designing around the illustrated clamp.

Turns ratio & duty

Np/Ns = VOR / (Vout + Vf) | D = VOR / (Vin,min + VOR)

The reflected voltage must fit the maximum low-line duty. Low-line peak is (Pout/η)/(Vin,min·D·(1 − Krp/2)). Then Lm = Vin,min·D/(fs·Krp·Ipk).

Winding currents

Irms = √[tfrac · (Ipk² + Ipk·Ivalley + Ivalley²)/3]

Primary and secondary RMS values use their conduction intervals. The secondary waveform uses primary-referred magnetizing current scaled by Np/Ns. At high line the model permits a DCM interval. Winding parasitics and loss allocation require a transformer design check.

Leakage clamp

Pclamp = ½ · Llk · Ipk² · fs · Vclamp / (Vclamp − VOR)

Use the highest modeled primary peak. With leakage, the drain screen uses Vin,max + Vclamp + ΔVclamp/2 and requires the clamp valley to remain above VOR. With zero leakage the model uses Vin,max + VOR. R is Vclamp²/Pclamp and C is approximated as Vclamp/(R·fs·ΔVclamp). Allow headroom for leakage tolerance and residual ringing.