Inductor Core Flux, Air Gap & Loss Calculator

Check peak flux and AC swing, calculate an equivalent air gap and estimate Steinmetz core loss.

Design inputs

Winding & geometry
Excitation & material
View live readout ↑

Live readout

Edit inputs
Peak flux
179.6 mT
Flux headroom
53.95 %
Air gap
0.76 mm
Core loss
0.03535 W
Core magnetization Core magnetization B–H reference BField H → Core gapPeak B180 mTSaturation390 mTAir gap0.76 mm
The B–H curve and gap are illustrative. The marker and labels follow the calculated flux and the selected material threshold.
Flux headroom available

Saturation uses the selected threshold. Check flux and inductance at operating temperature.

Peak flux / saturation179.6 mT / 390 mT

AC flux amplitude / saturation26.94 mT / 390 mT

Result breakdown
Peak flux density179.592 mT
Minimum flux density125.714 mT
AC flux swing (peak-to-peak)53.8776 mT
AC flux amplitude26.9388 mT
Midpoint DC current6.8 A
DC magnetizing field1,830.77 A/m
Material saturation threshold390 mT
Peak-flux headroom210.408 mT
Peak-flux headroom53.9508 %
Relative permeability used2,200
Equivalent discrete air gap0.760048 mm
Estimated ungapped inductance729.429 µH
Steinmetz coefficient k1.7592
Steinmetz frequency exponent α1.35893
Steinmetz flux exponent β2.09727
Modeled magnetic loss density9,712.63 W/m³
Modeled core loss0.035354 W

Formulas and assumptions

Flux

Bmax = L·Ipk/(N·Ae) | ΔB = L·ΔIpp/(N·Ae)

Compare the absolute endpoint flux with the saturation threshold. A bipolar peak-to-peak swing can exceed that threshold while both endpoints stay within it. Hdc = N·Idc/ℓe uses the midpoint of the entered triangular current. Use it with the actual powder-core DC-bias curve and enter inductance at the operating bias.

Gap

ℓg = μ₀·N²·Ae/L − ℓe/μr

If the computed gap is negative, the ungapped core cannot reach the target L at this turn count. The estimate neglects fringing and uses linear permeability. For a powder core the result is an equivalent reluctance, not a machining dimension.

Core loss

Pcore = Ve · k · fs^α · (ΔB/2)^β

Enter frequency in Hz and flux in tesla when fitting custom coefficients for a loss density in W/m³. Ferrite coefficients are approximate fits to typical hot datasheet points. Powder presets use published coefficients for representative 60-permeability toroids. Use your exact material, geometry, temperature and waveform for final loss estimates.