Catchment and storage

Rainwater Yield from a 1,000 ft² Asphalt Shingle Roof

Model runoff and a 1,250-gallon barrel system for a shingle roof serving a 30 gal/day landscape load.

Inputs

Annual water collected15,472.2 gal

Roof and storage

ft²
%Enter 0 to use the roof preset.
inEquivalent depth over the entire roof footprint.
gal/day
gal
%
Monthly weather
Rainfall by monthUse monthly rainfall for one site and design year.
in
in
in
in
in
in
in
in
in
in
in
in
First-flush events by monthCount qualifying storms for which the diverter resets.

Results

Updates as you edit
Annual water collected15,472.2 gal

The cistern covers the entered demand in this monthly design year.

Monthly cistern balance
Monthly cistern balanceMonthly averages cannot show the timing of individual storms or short dry spells.JanFebMarAprMayJunJulAugSepOctNovDec05161k1.5k2.1kMonthWater volume (gal)
  • End storage
  • Collected
  • Demand
  • Capacity

Monthly averages cannot show the timing of individual storms or short dry spells.

Diverter volume per qualifying storm
31.2 gal
Annual demand
10,950 gal
Unmet annual demand
0 gal
Annual overflow
3,647.2 gal
Idealized cyclic storage minimum
1,114.3 gal
December ending storage
1,250 gal
Annual first-flush diversion
1,932.5 gal

Worked calculation

  1. Estimate effective roof runoff

    Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient

    January: 1,000 ft² × 3.5 in × 80 % gives 1,745.5 gal.

  2. Subtract the first-flush diversion

    Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.

    Each qualifying storm diverts up to 31.2 gal. January collects 1,558.4 gal after diversion.

  3. Run the storage balance month by month

    New storage = prior storage + collection − demand, bounded by zero and cistern capacity.

    January starts with 375 gal, uses 930 gal and ends with 1,003.4 gal.

  4. Check the full year and longest deficit

    Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.

    The roof supplies 15,472.2 gal against 10,950 gal of demand. With a suitable starting fill, at least 1,114.3 gal bridges the modeled deficits.

Monthly storage ledger

All figures in gal.
MonthCollectedDemandEnd storageShortfallOverflow
Jan1,5589301,00300
Feb1,3598401,2500272
Mar1,6279301,2500697
Apr1,4099001,2500509
May1,5099301,2500579
Jun1,1729001,2500272
Jul45593077500
Aug38693023200
Sep80490013600
Oct1,49093069600
Nov1,8769001,2500422
Dec1,8269301,2500896

What this example shows

Rougher roof material yields less at the same rainfall and footprint. Enter a measured runoff coefficient if you have collection data for the roof.

Frequently asked questions

Why does the shingle roof preset capture less than the metal roof preset?

The planning factors allow for different wetting and surface losses. Actual collection also depends on gutter and filter performance.

Can I use all the asphalt roof area when one downspout is disconnected?

Include only the portion actually routed to storage. Estimate that contributing footprint from the gutters and drainage layout.