Catchment and storage

Rainwater Demand Deficit from a 300 ft² Shed Roof

Test a 300 ft² roof serving 50 gal/day and see why annual collection can limit coverage even with a larger cistern.

Inputs

Annual water collected5,083.9 gal

Roof and storage

ft²
%Enter 0 to use the roof preset.
inEquivalent depth over the entire roof footprint.
gal/day
gal
%
Monthly weather
Rainfall by monthUse monthly rainfall for one site and design year.
in
in
in
in
in
in
in
in
in
in
in
in
First-flush events by monthCount qualifying storms for which the diverter resets.

Results

Updates as you edit
Annual water collected5,083.9 gal

Annual collection falls short of annual demand. Starting storage can cover only a temporary deficit.

Monthly cistern balance
Monthly cistern balanceMonthly averages cannot show the timing of individual storms or short dry spells.JanFebMarAprMayJunJulAugSepOctNovDec04959901.5k2kMonthWater volume (gal)
  • End storage
  • Collected
  • Demand
  • Capacity

Monthly averages cannot show the timing of individual storms or short dry spells.

Diverter volume per qualifying storm
7.5 gal
Annual demand
18,250 gal
Unmet annual demand
11,366.1 gal
Annual overflow
0 gal
Idealized cyclic storage minimum
—
December ending storage
0 gal
Annual first-flush diversion
463.8 gal

Worked calculation

  1. Estimate effective roof runoff

    Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient

    January: 300 ft² × 3.5 in × 85 % gives 556.4 gal.

  2. Subtract the first-flush diversion

    Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.

    Each qualifying storm diverts up to 7.5 gal. January collects 511.5 gal after diversion.

  3. Run the storage balance month by month

    New storage = prior storage + collection − demand, bounded by zero and cistern capacity.

    January starts with 1,800 gal, uses 1,550 gal and ends with 761.5 gal.

  4. Check the full year and longest deficit

    Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.

    The roof supplies 5,083.9 gal against 18,250 gal of demand. Growing storage alone cannot cover the recurring annual deficit.

Monthly storage ledger

All figures in gal.
MonthCollectedDemandEnd storageShortfallOverflow
Jan5111,55076100
Feb4481,40001910
Mar5361,55001,0140
Apr4641,50001,0360
May4961,55001,0540
Jun3831,50001,1170
Jul1521,55001,3980
Aug1281,55001,4220
Sep2641,50001,2360
Oct4871,55001,0630
Nov6151,50008850
Dec5991,55009510

What this example shows

This example has a recurring annual shortfall. Vary the catchment footprint or demand to see which change could close the full-year water budget.

Frequently asked questions

What does an empty cyclic storage result mean for the shed?

Annual modeled collection is below annual demand. There is no finite tank size that makes the same roof self-sufficient on a repeating year.

Can a full tank make the first shed year look better?

Yes. Starting water adds a one-time supply. Look at annual collection against annual demand to see whether that draw is sustainable.