Total Dynamic Head (TDH) & Pump Curve Calculator
Add pumping water level, delivery pressure and pipe losses. Plot system head against a candidate pump curve.
Inputs
Results
Updates as you editThe candidate curve has sufficient head at the target flow.
- Hydraulic grade
- Pipe elevation
Straight-line elevation between the pumping water level and outlet. Fitting loss is grouped at the source.
- Static elevation lift
- 125 ft
- Outlet pressure head
- 71.63 ft
- Darcy straight-pipe loss
- 5.38 ft
- Hazen–Williams straight-pipe loss
- 5.06 ft
- Fitting loss
- 0.54 ft
- Pipe velocity
- 2.57 ft/s
- Pipe inside diameter
- 1.38 in
- Candidate head at target
- 221.84 ft
- Estimated intersection flow
- 14.43 gpm
- Estimated intersection head
- 204.85 ft
Inputs
- Target flow
- 12 gpm
- Static water depth
- 85 ft
- Pumping drawdown
- 30 ft
- Outlet above wellhead
- 10 ft
- Required outlet pressure
- 31 psig
- Pipe material
- PVC Schedule 40
- Nominal pipe size
- 1¼ in nominal
- Developed pipe length
- 250 ft
- Use friction method
- Darcy–Weisbach
- Water temperature
- 68 °F
- 90° elbows
- 3
- Check valves
- 1
- Additional fitting K
- 0
- Measured inside diameter
- 0 in
- Hazen–Williams C override
- 0
- Darcy roughness override
- 0 in
- Shutoff head at zero flow
- 260 ft
- Rated curve flow
- 20 gpm
- Head at rated curve flow
- 154 ft
Worked calculation
Find the pumping water level
Pumping depth = static depth + drawdown
85 ft + 30 ft = 115 ft below the wellhead. The outlet then gives 125 ft of static lift.
Convert delivery pressure to head
Hₚ = p / (ρg)
31 psig gives 71.63 ft of pressure head at the entered water temperature.
Add pipe and fitting losses
H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).
At 12 gpm the selected method adds 5.38 ft and fittings add 0.54 ft.
Build the duty point
TDH = static lift + pressure head + straight-pipe loss + fittings
125 ft + 71.63 ft + 5.38 ft + 0.54 ft = 202.54 ft.
Compare with the candidate pump
H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²
The candidate develops 221.84 ft at 12 gpm, a head difference of 19.3 ft.
Model and assumptions
Set the elevation reference
Pumping depth includes drawdown. The outlet elevation uses the wellhead as its reference. The tool models a single constant-diameter run and groups the fitting losses into one K. It neglects changes in velocity head between the end stations.
Use two pump curve points
Enter shutoff head and one published flow/head point at the operating speed. The quadratic gives an approximate intersection within that range. Use the full supplier curve for selection. The system curve assumes the entered pumping level holds across the flow range.
Engineering references
Frequently asked questions
How do I calculate total dynamic head from outlet pressure?
Divide gauge pressure by liquid density times gravity to find pressure head. For water near room temperature, 1 psi is about 2.31 ft of head. Add elevation and losses.
What if the calculated curve intersection is blank?
The entered pump curve and system curve do not cross within the fitted flow range. Enter more representative published pump data and check the target duty.