Well and transfer pumps

Total Dynamic Head (TDH) & Pump Curve Calculator

Add pumping water level, delivery pressure and pipe losses. Plot system head against a candidate pump curve.

Inputs

Total dynamic head202.54 ft

Duty point

gpm
ftWater level below the wellhead with the pump off.
ftAdditional drop in water level at the target flow.
ftUse a negative value for a lower outlet.
psigEnter 0 for an open tank.
ftMeasure along the pipe, including vertical runs.
Fittings and friction method
°F
K = 0.9 each for this estimate.
K = 2.5 each for this estimate.
Sum the K values for other fittings.
inEnter 0 to use the nominal-size table.
Enter 0 to use the material preset.
inEnter 0 to use the material preset.
Candidate pump curve
ft
gpm
ftUse a published point at the chosen speed.

Results

Updates as you edit
Total dynamic head202.54 ft

The candidate curve has sufficient head at the target flow.

Hydraulic grade profile
Hydraulic grade profileStraight-line elevation between the pumping water level and outlet. Fitting loss is grouped at the source.020406080100-126.14-67.66-9.1749.31107.8Pipe station (%)Head relative to wellhead (ft)Outlet grade · 81.63 ft
  • Hydraulic grade
  • Pipe elevation

Straight-line elevation between the pumping water level and outlet. Fitting loss is grouped at the source.

Static elevation lift
125 ft
Outlet pressure head
71.63 ft
Darcy straight-pipe loss
5.38 ft
Hazen–Williams straight-pipe loss
5.06 ft
Fitting loss
0.54 ft
Pipe velocity
2.57 ft/s
Pipe inside diameter
1.38 in
Candidate head at target
221.84 ft
Estimated intersection flow
14.43 gpm
Estimated intersection head
204.85 ft

Worked calculation

  1. Find the pumping water level

    Pumping depth = static depth + drawdown

    85 ft + 30 ft = 115 ft below the wellhead. The outlet then gives 125 ft of static lift.

  2. Convert delivery pressure to head

    Hₚ = p / (ρg)

    31 psig gives 71.63 ft of pressure head at the entered water temperature.

  3. Add pipe and fitting losses

    H𝒻 = f(L/D) v²/(2g) or 10.67 L(Q/C)¹·⁸⁵² / D⁴·⁸⁷⁰⁴ in SI. Hₖ = ΣK v²/(2g).

    At 12 gpm the selected method adds 5.38 ft and fittings add 0.54 ft.

  4. Build the duty point

    TDH = static lift + pressure head + straight-pipe loss + fittings

    125 ft + 71.63 ft + 5.38 ft + 0.54 ft = 202.54 ft.

  5. Compare with the candidate pump

    H(Q) = H₀ − (H₀ − H₁)(Q/Q₁)²

    The candidate develops 221.84 ft at 12 gpm, a head difference of 19.3 ft.

Model and assumptions

Set the elevation reference

Pumping depth includes drawdown. The outlet elevation uses the wellhead as its reference. The tool models a single constant-diameter run and groups the fitting losses into one K. It neglects changes in velocity head between the end stations.

Use two pump curve points

Enter shutoff head and one published flow/head point at the operating speed. The quadratic gives an approximate intersection within that range. Use the full supplier curve for selection. The system curve assumes the entered pumping level holds across the flow range.

Engineering references

Frequently asked questions

How do I calculate total dynamic head from outlet pressure?

Divide gauge pressure by liquid density times gravity to find pressure head. For water near room temperature, 1 psi is about 2.31 ft of head. Add elevation and losses.

What if the calculated curve intersection is blank?

The entered pump curve and system curve do not cross within the fitted flow range. Enter more representative published pump data and check the target duty.