Catchment and storage

Rainwater Cistern Sizing for a 2,000 ft² Metal Roof

Estimate collection for a 2,000 ft² metal roof and test whether a 5,000-gallon cistern covers 90 gal/day.

Inputs

Annual water collected38,244.2 gal

Roof and storage

ft²
%Enter 0 to use the roof preset.
inEquivalent depth over the entire roof footprint.
gal/day
gal
%
Monthly weather
Rainfall by monthUse monthly rainfall for one site and design year.
in
in
in
in
in
in
in
in
in
in
in
in
First-flush events by monthCount qualifying storms for which the diverter resets.

Results

Updates as you edit
Annual water collected38,244.2 gal

The cistern covers the entered demand in this monthly design year.

Monthly cistern balance
Monthly cistern balanceMonthly averages cannot show the timing of individual storms or short dry spells.JanFebMarAprMayJunJulAugSepOctNovDec01.4k2.7k4.1k5.5kMonthWater volume (gal)
  • End storage
  • Collected
  • Demand
  • Capacity

Monthly averages cannot show the timing of individual storms or short dry spells.

Diverter volume per qualifying storm
49.9 gal
Annual demand
32,850 gal
Unmet annual demand
0 gal
Annual overflow
2,894.2 gal
Idealized cyclic storage minimum
4,178.2 gal
December ending storage
5,000 gal
Annual first-flush diversion
3,091.9 gal

Worked calculation

  1. Estimate effective roof runoff

    Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient

    January: 2,000 ft² × 3.5 in × 95 % gives 4,145.5 gal.

  2. Subtract the first-flush diversion

    Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.

    Each qualifying storm diverts up to 49.9 gal. January collects 3,846.2 gal after diversion.

  3. Run the storage balance month by month

    New storage = prior storage + collection − demand, bounded by zero and cistern capacity.

    January starts with 2,500 gal, uses 2,790 gal and ends with 3,556.2 gal.

  4. Check the full year and longest deficit

    Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.

    The roof supplies 38,244.2 gal against 32,850 gal of demand. With a suitable starting fill, at least 4,178.2 gal bridges the modeled deficits.

Monthly storage ledger

All figures in gal.
MonthCollectedDemandEnd storageShortfallOverflow
Jan3,8462,7903,55600
Feb3,3722,5204,40900
Mar4,0332,7905,0000652
Apr3,4912,7005,0000791
May3,7282,7905,0000938
Jun2,8802,7005,0000180
Jul1,1532,7903,36300
Aug9662,7901,53900
Sep1,9822,70082200
Oct3,6592,7901,69100
Nov4,6252,7003,61600
Dec4,5072,7905,0000334

What this example shows

The 5,000-gallon cistern covers the modeled dry period. Reduce capacity below the cyclic estimate to see the first shortfall in the monthly table.

Frequently asked questions

Do I use sloped sheet area or roof footprint for the 2,000 ft² calculation?

Use the horizontal projection of the roof sections that drain to the cistern. Rain depth is measured over horizontal area.

How much water does one inch of rain yield on this metal roof before first flush?

One inch on 2,000 ft² is about 1,247 gallons before losses. At a 95% runoff factor, about 1,184 gallons reach the diverter.