Catchment and storage

First-Flush Diverter Size for a 600 ft² Greenhouse

Convert a 0.06-inch first-flush allowance to gallons and model a 600 ft² greenhouse roof through multiple monthly storms.

Inputs

Annual water collected10,393.4 gal

Roof and storage

ft²
%Enter 0 to use the roof preset.
inEquivalent depth over the entire roof footprint.
gal/day
gal
%
Monthly weather
Rainfall by monthUse monthly rainfall for one site and design year.
in
in
in
in
in
in
in
in
in
in
in
in
First-flush events by monthCount qualifying storms for which the diverter resets.

Results

Updates as you edit
Annual water collected10,393.4 gal

The cistern covers the entered demand in this monthly design year.

Monthly cistern balance
Monthly cistern balanceMonthly averages cannot show the timing of individual storms or short dry spells.JanFebMarAprMayJunJulAugSepOctNovDec0348.07696.141k1.4kMonthWater volume (gal)
  • End storage
  • Collected
  • Demand
  • Capacity

Monthly averages cannot show the timing of individual storms or short dry spells.

Diverter volume per qualifying storm
22.4 gal
Annual demand
4,380 gal
Unmet annual demand
0 gal
Annual overflow
5,413.4 gal
Idealized cyclic storage minimum
190.4 gal
December ending storage
800 gal
Annual first-flush diversion
1,615.8 gal

Worked calculation

  1. Estimate effective roof runoff

    Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient

    January: 600 ft² × 3.5 in × 92 % gives 1,204.4 gal.

  2. Subtract the first-flush diversion

    Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.

    Each qualifying storm diverts up to 22.4 gal. January collects 1,047.3 gal after diversion.

  3. Run the storage balance month by month

    New storage = prior storage + collection − demand, bounded by zero and cistern capacity.

    January starts with 200 gal, uses 372 gal and ends with 800 gal.

  4. Check the full year and longest deficit

    Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.

    The roof supplies 10,393.4 gal against 4,380 gal of demand. With a suitable starting fill, at least 190.4 gal bridges the modeled deficits.

Monthly storage ledger

All figures in gal.
MonthCollectedDemandEnd storageShortfallOverflow
Jan1,047372800075
Feb9323368000596
Mar1,0943728000722
Apr9443608000584
May1,0133728000641
Jun7823608000422
Jul31137273900
Aug24237261000
Sep53036077900
Oct9783728000586
Nov1,2663608000906
Dec1,2543728000882

What this example shows

The diverter volume is specified per qualifying storm. The model caps the monthly diverted volume at effective runoff, so a dry period cannot produce negative collection.

Frequently asked questions

Does first flush reset automatically for every rain shower?

Use the observed reset behavior and include only qualifying events. A partially drained diverter does not take a full new first flush.

How do I convert 0.06 inch on the greenhouse roof into diverter gallons?

Multiply depth in inches by 600 ft² and about 0.623 gal per ft²-inch. The result is about 22.4 gallons.