Rainwater Harvesting & Cistern Sizing Calculator
Estimate roof runoff and first flush, then see whether a cistern can bridge your driest months.
Inputs
Results
Updates as you editThe cistern covers the entered demand in this monthly design year.
- End storage
- Collected
- Demand
- Capacity
Monthly averages cannot show the timing of individual storms or short dry spells.
- Diverter volume per qualifying storm
- 49.9 gal
- Annual demand
- 32,850 gal
- Unmet annual demand
- 0 gal
- Annual overflow
- 2,894.2 gal
- Idealized cyclic storage minimum
- 4,178.2 gal
- December ending storage
- 5,000 gal
- Annual first-flush diversion
- 3,091.9 gal
Inputs
- Horizontal roof footprint
- 2,000 ft²
- Roof surface
- Smooth metal · 95%
- Runoff coefficient override
- 0 %
- First-flush depth per storm
- 0.04 in
- Daily water demand
- 90 gal/day
- Usable cistern capacity
- 5,000 gal
- January starting fill
- 50 %
- Rainfall by month
- Jan 3.5 in · Feb 3.1 in · Mar 3.7 in · Apr 3.2 in · May 3.4 in · Jun 2.6 in · Jul 1.1 in · Aug 0.9 in · Sep 1.8 in · Oct 3.3 in · Nov 4.2 in · Dec 4.1 in
- First-flush events by month
- Jan 6 · Feb 6 · Mar 7 · Apr 6 · May 6 · Jun 4 · Jul 3 · Aug 2 · Sep 3 · Oct 5 · Nov 7 · Dec 7
Worked calculation
Estimate effective roof runoff
Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient
January: 2,000 ft² × 3.5 in × 95 % gives 4,145.5 gal.
Subtract the first-flush diversion
Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.
Each qualifying storm diverts up to 49.9 gal. January collects 3,846.2 gal after diversion.
Run the storage balance month by month
New storage = prior storage + collection − demand, bounded by zero and cistern capacity.
January starts with 2,500 gal, uses 2,790 gal and ends with 3,556.2 gal.
Check the full year and longest deficit
Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.
The roof supplies 38,244.2 gal against 32,850 gal of demand. With a suitable starting fill, at least 4,178.2 gal bridges the modeled deficits.
Monthly storage ledger
| Month | Collected | Demand | End storage | Shortfall | Overflow |
|---|---|---|---|---|---|
| Jan | 3,846 | 2,790 | 3,556 | 0 | 0 |
| Feb | 3,372 | 2,520 | 4,409 | 0 | 0 |
| Mar | 4,033 | 2,790 | 5,000 | 0 | 652 |
| Apr | 3,491 | 2,700 | 5,000 | 0 | 791 |
| May | 3,728 | 2,790 | 5,000 | 0 | 938 |
| Jun | 2,880 | 2,700 | 5,000 | 0 | 180 |
| Jul | 1,153 | 2,790 | 3,363 | 0 | 0 |
| Aug | 966 | 2,790 | 1,539 | 0 | 0 |
| Sep | 1,982 | 2,700 | 822 | 0 | 0 |
| Oct | 3,659 | 2,790 | 1,691 | 0 | 0 |
| Nov | 4,625 | 2,700 | 3,616 | 0 | 0 |
| Dec | 4,507 | 2,790 | 5,000 | 0 | 334 |
Model and assumptions
Estimate collection by month
Use horizontal contributing roof area and local rainfall. Preset runoff coefficients are planning assumptions. The diverter removes an entered depth of water per qualifying storm, up to that month’s available runoff.
Plan for the sequence of dry months
The balance uses a 365-day calendar and nets monthly collection and demand before capping storage. The cyclic minimum assumes suitable January storage and the same rain pattern each year. Daily records can resolve storm timing and assess reliability.
Engineering references
Frequently asked questions
How much water is one inch of rain on one square foot?
One inch on one square foot is about 0.623 US gallons before roof and first-flush losses.
How do I interpret overflow in the monthly cistern table?
Overflow is modeled water beyond the tank capacity after netting that month’s demand. Short storms within the month may create different overflow in practice.