Catchment and storage

Rainwater Harvesting & Cistern Sizing Calculator

Estimate roof runoff and first flush, then see whether a cistern can bridge your driest months.

Inputs

Annual water collected38,244.2 gal

Roof and storage

ft²
%Enter 0 to use the roof preset.
inEquivalent depth over the entire roof footprint.
gal/day
gal
%
Monthly weather
Rainfall by monthUse monthly rainfall for one site and design year.
in
in
in
in
in
in
in
in
in
in
in
in
First-flush events by monthCount qualifying storms for which the diverter resets.

Results

Updates as you edit
Annual water collected38,244.2 gal

The cistern covers the entered demand in this monthly design year.

Monthly cistern balance
Monthly cistern balanceMonthly averages cannot show the timing of individual storms or short dry spells.JanFebMarAprMayJunJulAugSepOctNovDec01.4k2.7k4.1k5.5kMonthWater volume (gal)
  • End storage
  • Collected
  • Demand
  • Capacity

Monthly averages cannot show the timing of individual storms or short dry spells.

Diverter volume per qualifying storm
49.9 gal
Annual demand
32,850 gal
Unmet annual demand
0 gal
Annual overflow
2,894.2 gal
Idealized cyclic storage minimum
4,178.2 gal
December ending storage
5,000 gal
Annual first-flush diversion
3,091.9 gal

Worked calculation

  1. Estimate effective roof runoff

    Gross runoff = horizontal roof footprint × rainfall depth × runoff coefficient

    January: 2,000 ft² × 3.5 in × 95 % gives 4,145.5 gal.

  2. Subtract the first-flush diversion

    Diverter volume = footprint × first-flush depth. Monthly diversion is capped at that month’s roof runoff.

    Each qualifying storm diverts up to 49.9 gal. January collects 3,846.2 gal after diversion.

  3. Run the storage balance month by month

    New storage = prior storage + collection − demand, bounded by zero and cistern capacity.

    January starts with 2,500 gal, uses 2,790 gal and ends with 3,556.2 gal.

  4. Check the full year and longest deficit

    Sum each month. The largest cumulative monthly deficit sets the idealized cyclic storage minimum.

    The roof supplies 38,244.2 gal against 32,850 gal of demand. With a suitable starting fill, at least 4,178.2 gal bridges the modeled deficits.

Monthly storage ledger

All figures in gal.
MonthCollectedDemandEnd storageShortfallOverflow
Jan3,8462,7903,55600
Feb3,3722,5204,40900
Mar4,0332,7905,0000652
Apr3,4912,7005,0000791
May3,7282,7905,0000938
Jun2,8802,7005,0000180
Jul1,1532,7903,36300
Aug9662,7901,53900
Sep1,9822,70082200
Oct3,6592,7901,69100
Nov4,6252,7003,61600
Dec4,5072,7905,0000334

Model and assumptions

Estimate collection by month

Use horizontal contributing roof area and local rainfall. Preset runoff coefficients are planning assumptions. The diverter removes an entered depth of water per qualifying storm, up to that month’s available runoff.

Plan for the sequence of dry months

The balance uses a 365-day calendar and nets monthly collection and demand before capping storage. The cyclic minimum assumes suitable January storage and the same rain pattern each year. Daily records can resolve storm timing and assess reliability.

Engineering references

Frequently asked questions

How much water is one inch of rain on one square foot?

One inch on one square foot is about 0.623 US gallons before roof and first-flush losses.

How do I interpret overflow in the monthly cistern table?

Overflow is modeled water beyond the tank capacity after netting that month’s demand. Short storms within the month may create different overflow in practice.