Solar Well Pump & PV Array Sizing Calculator
Size a solar well pump from daily water demand and head. Compare PV watts, cistern volume and battery storage.
Inputs
Results
Updates as you editDirect pumping uses the larger of the daily energy and instantaneous power estimates.
The direct-power bar shows what the array would need to deliver at the design-sun condition without battery power.
- Required pump flow
- 3.33 gpm
- Pump electrical demand
- 224.1 W
- Daily hydraulic energy
- 0.471 kWh/day
- Daily pump electricity
- 1.121 kWh/day
- PV output factor
- 72.9 %
- Energy-limited array
- 307.6 W
- Direct-pumping power floor
- 307.6 W
- Cistern buffer equivalent
- 2,000 gal
- Nominal battery equivalent
- 3.04 kWh
- Battery capacity at bank voltage
- 63.4 Ah
Inputs
- Daily water target
- 1,000 gal/day
- Total dynamic head
- 150 ft
- Peak sun hours
- 5 h/day
- Actual pumping window
- 5 h/day
- Wire-to-water efficiency
- 42 %
- Operating mode
- Direct pump + cistern
- Storage autonomy
- 2 days
- Design PV cell temperature
- 131 °F
- Power loss per degree
- 0.222 %/°F
- Soiling loss
- 8 %
- Wiring and mismatch loss
- 10 %
- Tested well yield
- 0 gpm
- Battery round-trip efficiency
- 85 %
- Discharge-path efficiency
- 92 %
- Usable depth of discharge
- 80 %
- Battery bank voltage
- 48 V
Worked calculation
Set the pump duty
Q = daily volume / hours actually pumping
1,000 gal/day in 5 h/day gives 3.33 gpm at 150 ft of TDH.
Find the electrical energy at the pump
Ewater = ρgVH. Epump = Ewater / wire-to-water efficiency.
The water needs 0.471 kWh/day. At 42 % efficiency, the pump needs 1.121 kWh/day.
Derate the PV modules
PV factor = [1 − γ(Tcell − 25 °C)] × (1 − soiling) × (1 − other loss)
The temperature factor is 88 % and the combined output factor is 72.9 %.
Check daily energy and instantaneous power
Wenergy = daily pump Wh / (peak sun hours × PV factor × storage efficiency)
Daily energy gives 307.6 W. Direct pumping needs at least 307.6 W in the design-sun condition. The chosen mode yields 307.6 W.
Allow for storage autonomy
Cistern = daily volume × days. Nominal battery = pump kWh × days / (usable fraction × discharge efficiency).
2 days gives 2,000 gal of cistern storage or 3.04 kWh of nominal battery capacity.
Model and assumptions
Separate sun hours from pump hours
Peak sun hours describe equivalent solar energy at reference irradiance. Pump hours describe the actual delivery window. The array is a planning estimate from a daily energy balance and, for direct pumping, an instantaneous power floor.
Check equipment at the required flow and head
Use vendor output curves for actual array-to-water performance. Confirm operating voltage, cold open-circuit voltage, startup power, tested well yield and pump protection against the specific equipment limits.
Engineering references
Frequently asked questions
What does the cistern mode change in a solar pump array estimate?
It keeps the direct-drive PV power requirement and sets aside usable water storage. The pump fills the cistern during the pumping window.
Why compare both daily watt-hours and pump watts?
Daily energy can cover the target volume on paper while instantaneous output is insufficient to run the pump in the chosen window. Direct drive needs both.