Irrigation hydraulics

Drip & Sprinkler Irrigation Zone Calculator

Find zone flow, rainfall-equivalent application rate, lateral pressure loss and irrigation minutes per week.

Inputs

Total zone flow14.4 gpm

Zone layout

ft
in
ft
gal/h

Pipe bores and watering target

in
in
in
%
Lateral pressure budget
psigUse pressure after the filter, regulator and mainline.
psig
ftPositive uphill. The max-run estimate holds the slope constant.

Results

Updates as you edit
Total zone flow14.4 gpm

The entered pressure budget and 5 ft/s velocity screen are met.

Pressure along the critical lateral
Pressure along the critical lateralFlow drops at each outlet. The pressure model keeps each outlet at its rated flow.0367210814418004.959.914.8519.8Run distance (ft)Gauge pressure (psig)
  • Calculated pressure
  • Minimum outlet pressure

Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.

Gross precipitation rate
0.39 in/h
Weekly run time
183.3 min
Mainline velocity
3.09 ft/s
Critical lateral inlet velocity
2.49 ft/s
Critical lateral inlet flow
1.8 gpm
Outlets on critical lateral
180
Lateral friction drop
1.55 psi
Lowest lateral pressure
16.45 psig
Estimated maximum drip run
289 ft

Worked calculation

  1. Count outlets and total the flow

    Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.

    1,440 outlets give 14.4 gpm over 3,600 ft².

  2. Turn flow into application rate

    Gross depth per hour = hourly zone volume / wetted area

    The gross rate is 0.39 in/h and the net target is 1 in per week at 85 % efficiency.

  3. Calculate the weekly run time

    Minutes per week = 60 × target depth / (gross hourly rate × efficiency)

    The weekly runtime is 183.3 min.

  4. Track pressure down the lateral

    Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.

    Friction contributes 1.55 psi. Adding elevation gives a lowest gauge pressure of 16.45 psig. At the same slope, the pressure and velocity limits allow about 289 ft.

Model and assumptions

Account for the number and layout of outlets

The first outlet is one spacing from the inlet. Each segment carries the total flow of its downstream outlets. Sprinkler heads are distributed as evenly as possible between branches.

Check flow and pressure separately

The mainline check uses velocity. Enter the lateral inlet pressure after filter and supply-pipe losses. Maximum drip run is a constant-flow, constant-slope estimate restricted to 5,000 ft and 20,000 outlets. Verify pressure and uniformity with the emitter’s data.

Engineering references

Frequently asked questions

What should I enter for the weekly irrigation depth?

Enter the net water depth the irrigated area needs for the week after subtracting effective rainfall. Application efficiency accounts for the split between gross application and net delivery.

Why does pressure fall fastest at the lateral inlet?

Early segments carry water for more outlets. Higher flow makes friction loss per foot larger at the inlet.