Drip & Sprinkler Irrigation Zone Calculator
Find zone flow, rainfall-equivalent application rate, lateral pressure loss and irrigation minutes per week.
Inputs
Results
Updates as you editThe entered pressure budget and 5 ft/s velocity screen are met.
- Calculated pressure
- Minimum outlet pressure
Flow drops at each outlet. The pressure model keeps each outlet at its rated flow.
- Gross precipitation rate
- 0.39 in/h
- Weekly run time
- 183.3 min
- Mainline velocity
- 3.09 ft/s
- Critical lateral inlet velocity
- 2.49 ft/s
- Critical lateral inlet flow
- 1.8 gpm
- Outlets on critical lateral
- 180
- Lateral friction drop
- 1.55 psi
- Lowest lateral pressure
- 16.45 psig
- Estimated maximum drip run
- 289 ft
Inputs
- Emitter type
- Inline drip
- Parallel drip laterals
- 8
- Drip lateral length
- 180 ft
- Emitter spacing
- 12 in
- Lateral row spacing
- 2.5 ft
- Flow per drip emitter
- 0.6 gal/h
- Mainline inside diameter
- 1.38 in
- Lateral inside diameter
- 0.543 in
- Net weekly water depth
- 1 in
- Application efficiency
- 85 %
- Pressure at lateral entrance
- 18 psig
- Minimum outlet pressure
- 12 psig
- Elevation change along run
- 0 ft
- Lateral Hazen–Williams C
- 150
Worked calculation
Count outlets and total the flow
Emitters per line = floor(run length / spacing). Zone flow = total emitters × flow per emitter.
1,440 outlets give 14.4 gpm over 3,600 ft².
Turn flow into application rate
Gross depth per hour = hourly zone volume / wetted area
The gross rate is 0.39 in/h and the net target is 1 in per week at 85 % efficiency.
Calculate the weekly run time
Minutes per week = 60 × target depth / (gross hourly rate × efficiency)
The weekly runtime is 183.3 min.
Track pressure down the lateral
Each segment carries the flow for its remaining outlets. Segment head loss uses Hazen–Williams.
Friction contributes 1.55 psi. Adding elevation gives a lowest gauge pressure of 16.45 psig. At the same slope, the pressure and velocity limits allow about 289 ft.
Model and assumptions
Account for the number and layout of outlets
The first outlet is one spacing from the inlet. Each segment carries the total flow of its downstream outlets. Sprinkler heads are distributed as evenly as possible between branches.
Check flow and pressure separately
The mainline check uses velocity. Enter the lateral inlet pressure after filter and supply-pipe losses. Maximum drip run is a constant-flow, constant-slope estimate restricted to 5,000 ft and 20,000 outlets. Verify pressure and uniformity with the emitter’s data.
Engineering references
Frequently asked questions
What should I enter for the weekly irrigation depth?
Enter the net water depth the irrigated area needs for the week after subtracting effective rainfall. Application efficiency accounts for the split between gross application and net delivery.
Why does pressure fall fastest at the lateral inlet?
Early segments carry water for more outlets. Higher flow makes friction loss per foot larger at the inlet.