RG-213 vs RG-58 at 146 MHz over 100 Feet

Compare RG-213 and RG-58 feed loss for a 100 ft 2-meter amateur station run at 146 MHz, using Belden cable models.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 2.39dB

RG-213 · 50 Ω reference

Total feed loss
2.82 dB
At antenna input
34.18 dBm
EIRP
39.18 dBm
Matched coax loss comparisonMATCHED LOSS146 MHzRG-584.68 dBRG-17410.56 dBRG-2132.39 dBLMR-1953.93 dBLMR-2402.97 dBLMR-4001.52 dBLMR-6000.95 dBRG-62.24 dB
One-way cable loss at the same length and frequency for all eight models.

Feed loss & radiated power

Matched attenuation
2.39 dB / 100 ft
Matched attenuation, metric
7.84 dB / 100 m
Cable and connector loss
2.64 dB
Power at matched feed end
34.36 dBm
Additional load mismatch loss
0.18 dB
Conducted input reaching antenna
52.28 %
ERP
37.03 dBm
Data model
8267 · fit to published data

Worked example

For a 2-meter outdoor feed, compare the 100 ft matched losses for Belden 8267 RG-213 and 9201 RG-58. These models use catalog data near 146 MHz and can show how much improvement a thicker run buys at VHF.

Use the RX side of a link budget when judging weak repeaters or simplex stations. A better feed improves both directions. Check the age and condition of the installed outdoor line before using catalog loss to explain a weak signal.

Matched cable loss
2.39 dB
Total feed loss
2.82 dB
At antenna input
34.18 dBm
EIRP
39.18 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

Why compare these RG cables at 146 MHz instead of 900 MHz?

Coax loss rises with frequency, and the difference between types also changes. Use the transmit or receive frequency of the 2-meter station.

Does the modeled RG-58 have exactly 50 Ω impedance?

The named Belden 9201 part lists a nominal 52 Ω. Generic RG-58 construction labels can cover several products.