LMR-600 vs LMR-400 at 5.8 GHz

Compare nominal 5.8 GHz LMR-600 and LMR-400 attenuation on a 20 m microwave antenna feed.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 4.76dB

LMR-600 · 50 Ω reference

Total feed loss
5.2 dB
At antenna input
14.8 dBm
EIRP
32.8 dBm
Matched coax loss comparisonMATCHED LOSS5,800 MHzRG-5831.4* dBRG-17474.92* dBRG-21318.82* dBLMR-19517.29 dBLMR-24013.35 dBLMR-4007.1 dBLMR-6004.76 dBRG-611.25 dB
One-way cable loss at the same length and frequency for all eight models. An asterisk marks extrapolation past the source data.

Feed loss & radiated power

Matched attenuation
7.26 dB / 100 ft
Matched attenuation, metric
23.82 dB / 100 m
Cable and connector loss
5.16 dB
Power at matched feed end
14.84 dBm
Additional load mismatch loss
0.04 dB
Conducted input reaching antenna
30.19 %
ERP
30.65 dBm
Data model
LMR-600 · catalog coefficients

Worked example

The nominal coefficients give roughly 7.26 dB/100 ft for LMR-600 and 10.82 dB/100 ft for LMR-400 at 5.8 GHz. On 20 m, the larger cable preserves roughly 2.34 dB. Use the chart to see the same-length, matched comparison.

Check connector availability, bend radius and the cable’s weight if it hangs from a compact antenna. A lighter jumper adds its own frequency-specific loss and should be included in both transmit and receive budgets.

Matched cable loss
4.76 dB
Total feed loss
5.2 dB
At antenna input
14.8 dBm
EIRP
32.8 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

What improves when moving to LMR-600 on a 20 m 5.8 GHz run?

The nominal matched cable loss decreases by about 2.34 dB. The same antenna and connectors keep their own losses.

Do ultra-flex LMR-600 assemblies use the standard LMR-600 curve?

Check the specific assembly datasheet. Ultra-flex and other variants can have different attenuation coefficients.