LMR-400 Attenuation at 2.4 GHz over 100 Feet

Calculate LMR-400’s 100 ft loss at 2.4 GHz, the fraction of Wi-Fi transmit power left and how shortening the feed changes it.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 6.61dB

LMR-400 · 50 Ω reference

Total feed loss
6.61 dB
At antenna input
13.39 dBm
EIRP
21.39 dBm
Matched coax loss comparisonMATCHED LOSS2,400 MHzRG-5825.78* dBRG-17460.46* dBRG-21314.74 dBLMR-19516.51 dBLMR-24012.65 dBLMR-4006.61 dBLMR-6004.33 dBRG-610.2 dB
One-way cable loss at the same length and frequency for all eight models. An asterisk marks extrapolation past the source data.

Feed loss & radiated power

Matched attenuation
6.61 dB / 100 ft
Matched attenuation, metric
21.7 dB / 100 m
Cable and connector loss
6.61 dB
Power at matched feed end
13.39 dBm
Additional load mismatch loss
0 dB
Conducted input reaching antenna
21.8 %
ERP
19.24 dBm
Data model
LMR-400 · catalog coefficients

Worked example

At 2.4 GHz, 100 ft of the standard LMR-400 model loses about 6.61 dB. A little over one fifth of the transmitter power arrives at a matched load. Cut the cable input to 50 ft and the loss halves in dB.

If the radio can mount closer to the antenna, compare the outdoor enclosure or integrated radio layout with the coax run. Enter any short jumper and connector losses from the proposed layout before comparing EIRP.

Matched cable loss
6.61 dB
Total feed loss
6.61 dB
At antenna input
13.39 dBm
EIRP
21.39 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

Is the LMR-400 loss at 2.4 GHz exactly 6.8 dB per 100 feet?

The catalog’s 6.8 dB point is at 2.5 GHz. Its equation predicts about 6.61 dB per 100 ft at 2.4 GHz.

How much power remains after 100 ft of matched LMR-400 at 2.4 GHz?

Approximately 22% remains at the output in this loss-only preset.