75-Ohm RG-6 Loss at 600 MHz
Estimate 75 Ω Belden 1694A RG-6 attenuation at 600 MHz over a 30 m UHF receive run and account for connector loss.
Results
Preset estimateRG-6 · 75 Ω reference
- Total feed loss
- 5.15 dB
- At antenna input
- -5.15 dBm
- EIRP
- -5.15 dBm
Feed loss & radiated power
- Matched attenuation
- 4.73 dB / 100 ft
- Matched attenuation, metric
- 15.5 dB / 100 m
- Cable and connector loss
- 5.15 dB
- Power at matched feed end
- -5.15 dBm
- Additional load mismatch loss
- 0 dB
- Conducted input reaching antenna
- 30.54 %
- ERP
- -7.3 dBm
- Data model
- 1694A · fit to published data
Worked example
This example uses the matched loss of a 30 m 75 Ω feed for a UHF receive path. The RG-6 curve fits Belden 1694A. In a real receive budget, subtract the feed and connector loss from the antenna-port signal before comparing the tuner threshold.
If the receiver input is 50 Ω, measure the assembled transition or plan an impedance match. The matched loss in the comparison chart assumes each cable is used at its characteristic impedance.
- Matched cable loss
- 4.65 dB
- Total feed loss
- 5.15 dB
- At antenna input
- -5.15 dBm
- EIRP
- -5.15 dBm
Formulas & assumptions
- Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
- |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
- Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.
The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.
Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.
References
Questions & answers
Can a 600 MHz RG-6 insertion-loss number be used in a receive budget?
Yes. Use it for the feed section and add any connector or transition loss at the actual receive frequency.
Does the RG-6 preset include a 50-to-75 Ω adapter loss?
The preset uses a matched 75 Ω feed. Enter any measured adapter loss and the appropriate load VSWR separately.