75-Ohm RG-6 Loss at 600 MHz

Estimate 75 Ω Belden 1694A RG-6 attenuation at 600 MHz over a 30 m UHF receive run and account for connector loss.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 4.65dB

RG-6 · 75 Ω reference

Total feed loss
5.15 dB
At antenna input
-5.15 dBm
EIRP
-5.15 dBm
Matched coax loss comparisonMATCHED LOSS600 MHzRG-5810.47 dBRG-17423.99 dBRG-2135.6 dBLMR-1957.93 dBLMR-2406.03 dBLMR-4003.1 dBLMR-6001.97 dBRG-64.65 dB
One-way cable loss at the same length and frequency for all eight models.

Feed loss & radiated power

Matched attenuation
4.73 dB / 100 ft
Matched attenuation, metric
15.5 dB / 100 m
Cable and connector loss
5.15 dB
Power at matched feed end
-5.15 dBm
Additional load mismatch loss
0 dB
Conducted input reaching antenna
30.54 %
ERP
-7.3 dBm
Data model
1694A · fit to published data

Worked example

This example uses the matched loss of a 30 m 75 Ω feed for a UHF receive path. The RG-6 curve fits Belden 1694A. In a real receive budget, subtract the feed and connector loss from the antenna-port signal before comparing the tuner threshold.

If the receiver input is 50 Ω, measure the assembled transition or plan an impedance match. The matched loss in the comparison chart assumes each cable is used at its characteristic impedance.

Matched cable loss
4.65 dB
Total feed loss
5.15 dB
At antenna input
-5.15 dBm
EIRP
-5.15 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

Can a 600 MHz RG-6 insertion-loss number be used in a receive budget?

Yes. Use it for the feed section and add any connector or transition loss at the actual receive frequency.

Does the RG-6 preset include a 50-to-75 Ω adapter loss?

The preset uses a matched 75 Ω feed. Enter any measured adapter loss and the appropriate load VSWR separately.