LMR-240 Loss at 868 MHz over 15 Meters

Estimate LMR-240 loss for a 15 m 868 MHz feed and compare the gain left after connectors and load VSWR.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 3.65dB

LMR-240 · 50 Ω reference

Total feed loss
4.33 dB
At antenna input
5.67 dBm
EIRP
10.67 dBm
Matched coax loss comparisonMATCHED LOSS868 MHzRG-586.57 dBRG-17415.13 dBRG-2133.57 dBLMR-1954.79 dBLMR-2403.65 dBLMR-4001.88 dBLMR-6001.21 dBRG-62.84 dB
One-way cable loss at the same length and frequency for all eight models.

Feed loss & radiated power

Matched attenuation
7.42 dB / 100 ft
Matched attenuation, metric
24.34 dB / 100 m
Cable and connector loss
4.15 dB
Power at matched feed end
5.85 dBm
Additional load mismatch loss
0.18 dB
Conducted input reaching antenna
36.91 %
ERP
8.52 dBm
Data model
LMR-240 · catalog coefficients

Worked example

The 15 m run is about 49.21 ft. At 868 MHz the LMR-240 formula gives about 7.42 dB per 100 ft, so this length loses about 3.65 dB in the cable before connectors or mismatch.

The gain field is directional antenna gain. With a 5 dBi antenna, roughly half a decibel of connector loss and the displayed mismatch, most of the apparent gain is consumed by the feed. Compare the net EIRP with a short cable near the radio.

Matched cable loss
3.65 dB
Total feed loss
4.33 dB
At antenna input
5.67 dBm
EIRP
10.67 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

Is 15 m close enough to 50 ft for a quick 868 MHz cable estimate?

Yes for a rough check. The exact conversion used by the calculator is about 49.21 ft.

Where should an SMA pigtail go in the LMR-240 budget?