LMR-240 Loss at 868 MHz over 15 Meters
Estimate LMR-240 loss for a 15 m 868 MHz feed and compare the gain left after connectors and load VSWR.
Results
Preset estimateLMR-240 · 50 Ω reference
- Total feed loss
- 4.33 dB
- At antenna input
- 5.67 dBm
- EIRP
- 10.67 dBm
Feed loss & radiated power
- Matched attenuation
- 7.42 dB / 100 ft
- Matched attenuation, metric
- 24.34 dB / 100 m
- Cable and connector loss
- 4.15 dB
- Power at matched feed end
- 5.85 dBm
- Additional load mismatch loss
- 0.18 dB
- Conducted input reaching antenna
- 36.91 %
- ERP
- 8.52 dBm
- Data model
- LMR-240 · catalog coefficients
Worked example
The 15 m run is about 49.21 ft. At 868 MHz the LMR-240 formula gives about 7.42 dB per 100 ft, so this length loses about 3.65 dB in the cable before connectors or mismatch.
The gain field is directional antenna gain. With a 5 dBi antenna, roughly half a decibel of connector loss and the displayed mismatch, most of the apparent gain is consumed by the feed. Compare the net EIRP with a short cable near the radio.
- Matched cable loss
- 3.65 dB
- Total feed loss
- 4.33 dB
- At antenna input
- 5.67 dBm
- EIRP
- 10.67 dBm
Formulas & assumptions
- Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
- |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
- Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.
The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.
Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.
References
Questions & answers
Is 15 m close enough to 50 ft for a quick 868 MHz cable estimate?
Yes for a rough check. The exact conversion used by the calculator is about 49.21 ft.
Where should an SMA pigtail go in the LMR-240 budget?
Calculate its loss at 868 MHz from its own cable type and length. Add that and its connectors to the total feed-chain losses.