LMR-400 Loss at 915 MHz over 50 Feet

Calculate 50 ft of LMR-400 loss at 915 MHz and see how 1.5:1 antenna VSWR and connector loss affect Meshtastic EIRP.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 1.97dB

LMR-400 · 50 Ω reference

Total feed loss
2.45 dB
At antenna input
17.55 dBm
EIRP
20.55 dBm
Matched coax loss comparisonMATCHED LOSS915 MHzRG-586.89 dBRG-17415.9 dBRG-2133.76 dBLMR-1955 dBLMR-2403.81 dBLMR-4001.97 dBLMR-6001.26 dBRG-62.97 dB
One-way cable loss at the same length and frequency for all eight models.

Feed loss & radiated power

Matched attenuation
3.94 dB / 100 ft
Matched attenuation, metric
12.92 dB / 100 m
Cable and connector loss
2.27 dB
Power at matched feed end
17.73 dBm
Additional load mismatch loss
0.18 dB
Conducted input reaching antenna
56.94 %
ERP
18.4 dBm
Data model
LMR-400 · catalog coefficients

Worked example

The Times Microwave curve gives about 3.94 dB per 100 ft at 915 MHz. Over 50 ft, the matched cable costs about 1.97 dB. This preset adds 0.30 dB of connector loss and about 0.177 dB from the 1.5:1 antenna VSWR.

To compare cable and height, try a longer run and use the resulting loss in a link budget alongside a Fresnel check. A higher antenna can improve terrain clearance while consuming more feed-line budget.

Matched cable loss
1.97 dB
Total feed loss
2.45 dB
At antenna input
17.55 dBm
EIRP
20.55 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

How much coax-only loss does 50 ft of LMR-400 have at 915 MHz?

About 1.97 dB using the nominal manufacturer curve. Connectors and antenna mismatch are added separately.

Can a longer coax run reduce my 915 MHz receive signal too?

Yes. Cable and connector insertion loss reduce power reaching the receiver as well as transmit power reaching the antenna.