Worked example · Deck foundations

26-Inch Pier for a 100 ft² Deck Post on 3,000 psf Soil

Use a specified 26 in. cylinder for each of three 6×6 posts. Each post carries 100 ft² and the model uses a 54 in. concrete depth.

Example inputs

Supported deck area
ft
ft
ft
psf
Footing and soil
in
Enter the local frost-protected requirement.
in
0 uses the rounded diameter screen.
Axial column inputs
psi
psi
See results

Worked result

Updates as you type
Gravity load per post
5,000 lb
Rounded footing diameter screen
20 in
IRC Southern Pine post height
14 ft

Tributary area and pier section

Schematic
Tributary area and pier section 10 ft10 ft100 ft²Tributary area5,000 lb7 ft54 in26 in

Calculation details

Gravity load per post
5,000 lb
Rounded footing diameter screen
20 in
IRC Southern Pine post height
14 ft
Post tributary area
100 ft²
Modeled axial column capacity
22,992 lb
Column slenderness Le/d
15.3
Column stability Cp
0.845
R507.3.1 round footing minimum
17 in
R507.3.1 plain footing thickness
6 in
Diameter for entered soil capacity
19.86 in
Modeled pier diameter
26 in
Gross soil pressure
2,031 psf
Pier bottom below grade
54 in
Concrete per full-depth pier
16.592 ft³
Concrete across all piers
1.844 yd³

Checks and references

  • Within limit
    R507.4 post height

    The table screen assumes Southern Pine No. 2 in wet service. Measure from footing top to beam underside.

  • Within limit
    Axial column stability

    The NDS-style stability screen uses K = 1, Le/d ≤ 50 and the adjusted properties entered. Confirm actual restraint and combined loading.

  • Within limit
    R507.3.1 round footing

    The 2021 IRC screen uses the next applicable load band and interpolates within table areas and soil values.

  • Within limit
    Bearing and post fit

    Gross pressure includes 150 lb/ft³ concrete. The footing must support the full square post footprint. Check anchor edge distances separately.

  • Reference
    Frost protection

    Footing bottoms use the larger of 12 in. and the entered local requirement. Confirm frost protection, site soil and footing detail with the local authority.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Find the post tributary load

    10 ft × 10 ft = 100 ft². Multiply by 10 psf dead plus the larger of 40 psf live and ground snow for 5,000 lb.

  2. Screen the post as a column

    Use effective length K × height and a 5.5 in actual side. Le/d = 15.27. Apply the column stability factor Cp = 0.845 to the adjusted compression stress.

  3. Check the footing diameter

    Use R507.3.1 and the entered soil capacity. For the gross-pressure screen, divide post load by soil capacity less the pier self-weight per square foot, then solve the circle area for diameter.

  4. Estimate the pier concrete

    A 26 in diameter cylinder to 54 in below grade holds 16.59 ft³ per pier and yields 2,031 psf gross bearing pressure.

Frequently asked questions

How much concrete does one 26 in. by 54 in. deck pier hold?

A full cylinder holds π × (26/24)² × 4.5, about 16.59 ft³.

What should I enter when plans already specify a 26 in. footing?

Enter 26 in. as the selected diameter to compare that plan size with the table and modeled gross bearing pressure.

Other calculators