Worked example · Deck foundations

6×6 vs. 4×4 Deck Post at 10 ft High

An 8 ft by 10 ft tributary rectangle feeds a post standing 10 ft between pier and beam. Start with a 4×4 and use the stock selector to compare a 6×6.

Example inputs

Supported deck area
ft
ft
ft
psf
Footing and soil
in
Enter the local frost-protected requirement.
in
0 uses the rounded diameter screen.
Axial column inputs
psi
psi
See results

Worked result

Updates as you type
Gravity load per post
4,000 lb
Rounded footing diameter screen
27 in
IRC Southern Pine post height
9 ft 5 in

Tributary area and pier section

Schematic
Tributary area and pier section 8 ft10 ft80 ft²Tributary area4,000 lb10 ft36 in27 in

Calculation details

Gravity load per post
4,000 lb
Rounded footing diameter screen
27 in
IRC Southern Pine post height
9 ft 5 in
Post tributary area
80 ft²
Modeled axial column capacity
3,524 lb
Column slenderness Le/d
34.3
Column stability Cp
0.32
R507.3.1 round footing minimum
22 in
R507.3.1 plain footing thickness
7 in
Diameter for entered soil capacity
26.43 in
Modeled pier diameter
27 in
Gross soil pressure
1,456 psf
Pier bottom below grade
36 in
Concrete per full-depth pier
11.928 ft³
Concrete across all piers
1.325 yd³

Checks and references

  • Review
    R507.4 post height

    The table screen assumes Southern Pine No. 2 in wet service. Measure from footing top to beam underside.

  • Review
    Axial column stability

    The NDS-style stability screen uses K = 1, Le/d ≤ 50 and the adjusted properties entered. Confirm actual restraint and combined loading.

  • Within limit
    R507.3.1 round footing

    The 2021 IRC screen uses the next applicable load band and interpolates within table areas and soil values.

  • Within limit
    Bearing and post fit

    Gross pressure includes 150 lb/ft³ concrete. The footing must support the full square post footprint. Check anchor edge distances separately.

  • Reference
    Frost protection

    Footing bottoms use the larger of 12 in. and the entered local requirement. Confirm frost protection, site soil and footing detail with the local authority.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Find the post tributary load

    8 ft × 10 ft = 80 ft². Multiply by 10 psf dead plus the larger of 40 psf live and ground snow for 4,000 lb.

  2. Screen the post as a column

    Use effective length K × height and a 3.5 in actual side. Le/d = 34.29. Apply the column stability factor Cp = 0.32 to the adjusted compression stress.

  3. Check the footing diameter

    Use R507.3.1 and the entered soil capacity. For the gross-pressure screen, divide post load by soil capacity less the pier self-weight per square foot, then solve the circle area for diameter.

  4. Estimate the pier concrete

    A 27 in diameter cylinder to 36 in below grade holds 11.93 ft³ per pier and yields 1,456 psf gross bearing pressure.

Frequently asked questions

What is the 4×4 Southern Pine height row at 80 ft² under the live load case?

R507.4 lists 9 ft 5 in. The proposed ten-foot post exceeds that row.

What changes when I switch the 10 ft post example to 6×6?

The selected 6×6 row gives 14 ft under the same live-load case. The larger actual width also reduces slenderness.

Other calculators