12×16 Deck Outer Center Post with a 2,700 lb Reaction

The outer beam supports an equivalent 7.2 ft width over a 7.5 ft bay. Use those dimensions to preserve the modeled 2,700 lb center-post reaction from the framing example.

Example inputs

Supported deck area
ft
ft
ft
psf
Footing and soil
in
Enter the local frost-protected requirement.
in
0 uses the rounded diameter screen.
Axial column inputs
psi
psi
See results

Worked result

Updates as you type
Gravity load per post
2,700 lb
Rounded footing diameter screen
23 in
IRC Southern Pine post height
14 ft

Tributary area and pier section

Schematic
Tributary area and pier section 7.2 ft7.5 ft54 ft²Tributary area2,700 lb5 ft42 in23 in

Calculation details

Gravity load per post
2,700 lb
Rounded footing diameter screen
23 in
IRC Southern Pine post height
14 ft
Post tributary area
54 ft²
Modeled axial column capacity
25,353 lb
Column slenderness Le/d
10.9
Column stability Cp
0.931
R507.3.1 round footing minimum
19 in
R507.3.1 plain footing thickness
6 in
Diameter for entered soil capacity
22.53 in
Modeled pier diameter
23 in
Gross soil pressure
1,461 psf
Pier bottom below grade
42 in
Concrete per full-depth pier
10.098 ft³
Concrete across all piers
0.374 yd³

Checks and references

  • Within limit
    R507.4 post height

    The table screen assumes Southern Pine No. 2 in wet service. Measure from footing top to beam underside.

  • Within limit
    Axial column stability

    The NDS-style stability screen uses K = 1, Le/d ≤ 50 and the adjusted properties entered. Confirm actual restraint and combined loading.

  • Within limit
    R507.3.1 round footing

    The 2021 IRC screen uses the next applicable load band and interpolates within table areas and soil values.

  • Within limit
    Bearing and post fit

    Gross pressure includes 150 lb/ft³ concrete. The footing must support the full square post footprint. Check anchor edge distances separately.

  • Reference
    Frost protection

    Footing bottoms use the larger of 12 in. and the entered local requirement. Confirm frost protection, site soil and footing detail with the local authority.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Find the post tributary load

    7.2 ft × 7.5 ft = 54 ft². Multiply by 10 psf dead plus the larger of 40 psf live and ground snow for 2,700 lb.

  2. Screen the post as a column

    Use effective length K × height and a 5.5 in actual side. Le/d = 10.91. Apply the column stability factor Cp = 0.931 to the adjusted compression stress.

  3. Check the footing diameter

    Use R507.3.1 and the entered soil capacity. For the gross-pressure screen, divide post load by soil capacity less the pier self-weight per square foot, then solve the circle area for diameter.

  4. Estimate the pier concrete

    A 23 in diameter cylinder to 42 in below grade holds 10.1 ft³ per pier and yields 1,461 psf gross bearing pressure.

Frequently asked questions

What width reproduces the 12×16 outer center-post load?

Use 7.2 ft of reaction-equivalent width and a 7.5 ft bay. The 54 ft² equivalent area times 50 psf gives 2,700 lb.

Why set one identical pier for the outer center-post takeoff?

End posts and inner support posts can have different reactions. Estimating the center pier separately keeps its concrete volume visible.

Other calculators