Worked example · Deck foundations

6×6 Deck Post at 80 ft² with 60 psf Ground Snow

A 10 ft 6×6 post carries a tributary rectangle of 8×10 ft. At 60 psf ground snow, the deck surface produces 70 psf including dead load.

Example inputs

Supported deck area
ft
ft
ft
psf
Footing and soil
in
Enter the local frost-protected requirement.
in
0 uses the rounded diameter screen.
Axial column inputs
psi
psi
See results

Worked result

Updates as you type
Gravity load per post
5,600 lb
Rounded footing diameter screen
34 in
IRC Southern Pine post height
14 ft

Tributary area and pier section

Schematic
Tributary area and pier section 8 ft10 ft80 ft²Tributary area5,600 lb10 ft48 in34 in

Calculation details

Gravity load per post
5,600 lb
Rounded footing diameter screen
34 in
IRC Southern Pine post height
14 ft
Post tributary area
80 ft²
Modeled axial column capacity
17,375 lb
Column slenderness Le/d
21.8
Column stability Cp
0.638
R507.3.1 round footing minimum
26 in
R507.3.1 plain footing thickness
9 in
Diameter for entered soil capacity
33.78 in
Modeled pier diameter
34 in
Gross soil pressure
1,488 psf
Pier bottom below grade
48 in
Concrete per full-depth pier
25.22 ft³
Concrete across all piers
2.802 yd³

Checks and references

  • Within limit
    R507.4 post height

    The table screen assumes Southern Pine No. 2 in wet service. Measure from footing top to beam underside.

  • Within limit
    Axial column stability

    The NDS-style stability screen uses K = 1, Le/d ≤ 50 and the adjusted properties entered. Confirm actual restraint and combined loading.

  • Within limit
    R507.3.1 round footing

    The 2021 IRC screen uses the next applicable load band and interpolates within table areas and soil values.

  • Within limit
    Bearing and post fit

    Gross pressure includes 150 lb/ft³ concrete. The footing must support the full square post footprint. Check anchor edge distances separately.

  • Reference
    Frost protection

    Footing bottoms use the larger of 12 in. and the entered local requirement. Confirm frost protection, site soil and footing detail with the local authority.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Find the post tributary load

    8 ft × 10 ft = 80 ft². Multiply by 10 psf dead plus the larger of 40 psf live and ground snow for 5,600 lb.

  2. Screen the post as a column

    Use effective length K × height and a 5.5 in actual side. Le/d = 21.82. Apply the column stability factor Cp = 0.638 to the adjusted compression stress.

  3. Check the footing diameter

    Use R507.3.1 and the entered soil capacity. For the gross-pressure screen, divide post load by soil capacity less the pier self-weight per square foot, then solve the circle area for diameter.

  4. Estimate the pier concrete

    A 34 in diameter cylinder to 48 in below grade holds 25.22 ft³ per pier and yields 1,488 psf gross bearing pressure.

Frequently asked questions

What gravity load does the 60 psf snow case put on this 6×6 post?

The governing 70 psf total surface load times 80 ft² produces 5,600 lb above the footing.

Which diameter row applies to 80 ft² at 60 psf ground snow and 1,500 psf soil?

The 2021 IRC table gives a 26 in. round footing. Gross pressure and concrete self-weight are checked separately.