Worked example
Cold-Climate OSB Behind an R-19 Cavity
An auditor checks the indoor face of OSB at a 10°F outdoor condition. The cavity and interior finish total R-20. The outer layers and continuous insulation total R-10.
Try it Increase the exterior foam R until the sheathing crosses the dew point line. Compare the result with the threshold shown below the chart.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Sheathing temperature
- °F
- Indoor dew point
- °F
- Margin above dew point
- °F
Condensation risk at the sheathing if exposed to indoor air under these conditions.
Temperature through the wall
- Exterior foam R at dew-point threshold
- R
- Total cavity-path R
- R
- R inboard of sheathing
- R
Inputs used
- Indoor temperature
- 70 °F
- Indoor relative humidity
- 35 %
- Outdoor temperature
- 10 °F
- Interior film and finish R
- 1 R
- Cavity insulation R
- 19 R
- Sheathing, exterior film and other outboard R
- 1 R
- Continuous exterior foam R
- 9 R
How this calculation works
The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.
The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.
This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.
References
Frequently asked questions
Why is the OSB only 30°F in this cold-climate wall?
The inboard portion is two-thirds of the total thermal resistance. Two-thirds of the 60°F temperature difference therefore occurs before the OSB interface.
Does this OSB check tell me how many hours it will be wet?
It compares conditions at one point in time. Estimating duration and drying requires hourly weather, moisture transport and material storage.