Worked example
Winter Sheathing Check for a Humidified Home
A homeowner runs a humidifier at 55% indoor RH and 72°F. The wall has R-15 inboard of the sheathing, R-5 outboard and a representative outdoor condition of 22°F.
Try it Lower indoor RH to 35% while holding the wall and outdoor temperature fixed. The sheathing temperature stays put while the dew point drops.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Sheathing temperature
- °F
- Indoor dew point
- °F
- Margin above dew point
- °F
Condensation risk at the sheathing if exposed to indoor air under these conditions.
Temperature through the wall
- Exterior foam R at dew-point threshold
- R
- Total cavity-path R
- R
- R inboard of sheathing
- R
Inputs used
- Indoor temperature
- 72 °F
- Indoor relative humidity
- 55 %
- Outdoor temperature
- 22 °F
- Interior film and finish R
- 1 R
- Cavity insulation R
- 14 R
- Sheathing, exterior film and other outboard R
- 1 R
- Continuous exterior foam R
- 4 R
How this calculation works
The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.
The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.
This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.
References
Frequently asked questions
What changes first when I turn down the winter humidifier?
In this calculation, lower indoor humidity lowers the dew point. Wall temperatures depend on the temperature difference and thermal resistances.
Which humidity reading should I use if bedrooms are damper overnight?
Run a case with a representative upper overnight reading and another with a typical daytime reading. Choose measurements near the area of concern.