Winter Sheathing Check for a Humidified Home

A homeowner runs a humidifier at 55% indoor RH and 72°F. The wall has R-15 inboard of the sheathing, R-5 outboard and a representative outdoor condition of 22°F.

Try it Lower indoor RH to 35% while holding the wall and outdoor temperature fixed. The sheathing temperature stays put while the dew point drops.

Air conditions
°F
%
°F
Insulation and layers
R
R
R
R

The interface is the indoor-facing side of the sheathing.

Sheathing temperature
34.5 °F
Indoor dew point
55 °F
Margin above dew point
-20.5 °F

Condensation risk at the sheathing if exposed to indoor air under these conditions.

Temperature through the wall

Temperature and indoor dew point through the wallIndoor dew point 55 °F. Sheathing 34.5 °F. 1732476277°FWall temperatureIndoor dew pointInsideOutsideCumulative resistanceSheathing 34.5 °F
Horizontal position follows cumulative thermal resistance. The dashed line is the indoor dew point.
Exterior foam R at dew-point threshold
28 R
Total cavity-path R
20 R
R inboard of sheathing
15 R
Download

How this calculation works

The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.

The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.

This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.

References

Frequently asked questions

What changes first when I turn down the winter humidifier?

In this calculation, lower indoor humidity lowers the dew point. Wall temperatures depend on the temperature difference and thermal resistances.

Which humidity reading should I use if bedrooms are damper overnight?

Run a case with a representative upper overnight reading and another with a typical daytime reading. Choose measurements near the area of concern.