Worked example
Marine-Climate Wall with Exterior EPS
A crew plans a marine-climate siding retrofit with R-9 of exterior EPS. The inside is 68°F and 50% RH, the outdoor check is 40°F, and the cavity-plus-interior path is R-15.
Try it Reduce the exterior foam to R-5 in the calculator and compare the margin above dew point to the full R-9 design.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Sheathing temperature
- °F
- Indoor dew point
- °F
- Margin above dew point
- °F
The sheathing is above indoor dew point by less than 3°F (1.7 K). Small changes can use up that margin.
Temperature through the wall
- Exterior foam R at dew-point threshold
- R
- Total cavity-path R
- R
- R inboard of sheathing
- R
Inputs used
- Indoor temperature
- 68 °F
- Indoor relative humidity
- 50 %
- Outdoor temperature
- 40 °F
- Interior film and finish R
- 1 R
- Cavity insulation R
- 14 R
- Sheathing, exterior film and other outboard R
- 1 R
- Continuous exterior foam R
- 9 R
How this calculation works
The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.
The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.
This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.
References
Frequently asked questions
Why check a 40°F day for a marine-climate retrofit?
Long stretches near that condition can be relevant to winter moisture exposure. Run additional cases for local design conditions and expected indoor humidity.
Does the EPS wall result account for rain behind the siding?
Rain entry and drainage are separate moisture loads. The modeled EPS value only affects the temperature profile, so check the drainage plane and detailing independently.