A Warm Outdoor Day with a Reverse Wall Gradient

A contractor checks a shoulder-season hour when the house is 66°F and the outdoor air is 74°F. The wall has R-18 inboard and R-6 outboard of the sheathing interface.

Try it Change the outdoor temperature from 74°F to 30°F. The same wall now has an outward winter gradient and the foam threshold may become positive.

Air conditions
°F
%
°F
Insulation and layers
R
R
R
R

The interface is the indoor-facing side of the sheathing.

Sheathing temperature
72 °F
Indoor dew point
51.7 °F
Margin above dew point
20.3 °F

The temperature gradient is inward. This screen compares the sheathing with indoor dew point only.

Temperature through the wall

Temperature and indoor dew point through the wallIndoor dew point 51.7 °F. Sheathing 72 °F. 4755637179°FWall temperatureIndoor dew pointInsideOutsideCumulative resistanceSheathing 72 °F
Horizontal position follows cumulative thermal resistance. The dashed line is the indoor dew point.
Exterior foam R at dew-point threshold
0 R
Total cavity-path R
24 R
R inboard of sheathing
18 R
Download

How this calculation works

The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.

The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.

This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.

References

Frequently asked questions

Why is the interface warmer than the indoor air in this shoulder-season case?

The outdoor side is warmer, so temperature increases moving across the assembly from inside to outside.

Can a reverse temperature gradient still present a summer moisture concern?

Yes. Humid outside air, vapor drive and air-conditioned surfaces can cause inward moisture problems. This calculator compares the interface with indoor dew point.