Worked example
A Warm Outdoor Day with a Reverse Wall Gradient
A contractor checks a shoulder-season hour when the house is 66°F and the outdoor air is 74°F. The wall has R-18 inboard and R-6 outboard of the sheathing interface.
Try it Change the outdoor temperature from 74°F to 30°F. The same wall now has an outward winter gradient and the foam threshold may become positive.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Sheathing temperature
- °F
- Indoor dew point
- °F
- Margin above dew point
- °F
The temperature gradient is inward. This screen compares the sheathing with indoor dew point only.
Temperature through the wall
- Exterior foam R at dew-point threshold
- R
- Total cavity-path R
- R
- R inboard of sheathing
- R
Inputs used
- Indoor temperature
- 66 °F
- Indoor relative humidity
- 60 %
- Outdoor temperature
- 74 °F
- Interior film and finish R
- 1 R
- Cavity insulation R
- 17 R
- Sheathing, exterior film and other outboard R
- 2 R
- Continuous exterior foam R
- 4 R
How this calculation works
The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.
The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.
This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.
References
Frequently asked questions
Why is the interface warmer than the indoor air in this shoulder-season case?
The outdoor side is warmer, so temperature increases moving across the assembly from inside to outside.
Can a reverse temperature gradient still present a summer moisture concern?
Yes. Humid outside air, vapor drive and air-conditioned surfaces can cause inward moisture problems. This calculator compares the interface with indoor dew point.