Worked example
Low-Humidity Cabin at −10°F Outside
A seasonal cabin sits at 65°F and 25% RH during a cold night. R-14 continuous insulation makes the portion outside the interface as resistant as the R-15 inside.
Try it Move outdoor temperature ten degrees warmer and compare the margin. Then test a more humid occupied weekend at the original outdoor temperature.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Sheathing temperature
- °F
- Indoor dew point
- °F
- Margin above dew point
- °F
Condensation risk at the sheathing if exposed to indoor air under these conditions.
Temperature through the wall
- Exterior foam R at dew-point threshold
- R
- Total cavity-path R
- R
- R inboard of sheathing
- R
Inputs used
- Indoor temperature
- 65 °F
- Indoor relative humidity
- 25 %
- Outdoor temperature
- -10 °F
- Interior film and finish R
- 1 R
- Cavity insulation R
- 14 R
- Sheathing, exterior film and other outboard R
- 1 R
- Continuous exterior foam R
- 14 R
How this calculation works
The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.
The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.
This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.
References
Frequently asked questions
Why can the cabin sheathing still be near dew point at 25% indoor RH?
The outdoor temperature is very low and roughly half the total temperature drop occurs before the interface. Low humidity lowers dew point without raising sheathing temperature.
Which cabin condition should I check besides the coldest night?
Use a typical cold spell and indoor humidity while the cabin is occupied. Cooking, showers and occupancy can shift the dew point.