Low-Humidity Cabin at −10°F Outside

A seasonal cabin sits at 65°F and 25% RH during a cold night. R-14 continuous insulation makes the portion outside the interface as resistant as the R-15 inside.

Try it Move outdoor temperature ten degrees warmer and compare the margin. Then test a more humid occupied weekend at the original outdoor temperature.

Air conditions
°F
%
°F
Insulation and layers
R
R
R
R

The interface is the indoor-facing side of the sheathing.

Sheathing temperature
27.5 °F
Indoor dew point
28.3 °F
Margin above dew point
-0.8 °F

Condensation risk at the sheathing if exposed to indoor air under these conditions.

Temperature through the wall

Temperature and indoor dew point through the wallIndoor dew point 28.3 °F. Sheathing 27.5 °F. -156284970°FWall temperatureIndoor dew pointInsideOutsideCumulative resistanceSheathing 27.5 °F
Horizontal position follows cumulative thermal resistance. The dashed line is the indoor dew point.
Exterior foam R at dew-point threshold
14.66 R
Total cavity-path R
30 R
R inboard of sheathing
15 R
Download

How this calculation works

The Magnus equation estimates indoor dew point from indoor temperature and relative humidity. The interface temperature is T_inside − (T_inside − T_outside) × R_inboard ÷ R_total.

The calculator solves for the exterior foam R where the interface just reaches the indoor dew point. The result is a threshold for this one set of conditions. A practical assembly needs a margin and a documented plan for drying.

This is a steady-state cavity-path screen for exposure to indoor air. It omits vapor diffusion, rain, solar heating, heat storage, moisture buffering, framing effects and summertime inward vapor drive.

References

Frequently asked questions

Why can the cabin sheathing still be near dew point at 25% indoor RH?

The outdoor temperature is very low and roughly half the total temperature drop occurs before the interface. Low humidity lowers dew point without raising sheathing temperature.

Which cabin condition should I check besides the coldest night?

Use a typical cold spell and indoor humidity while the cabin is occupied. Cooking, showers and occupancy can shift the dew point.