4 MGD Conventional Activated Sludge
Work through F/M, 7.17 days MCRT, SVI and carbon plus nitrification oxygen demand in a 4 MGD train.
Biological treatment
Calculate F/M, sludge age, SVI and a planning estimate of carbonaceous and nitrification oxygen demand for an aeration train.
For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.
Work through F/M, 7.17 days MCRT, SVI and carbon plus nitrification oxygen demand in a 4 MGD train.
Calculate F/M of about 0.042 d⁻¹, solids age and carbon-only oxygen demand for a 1.2 MGD extended aeration train.
Use a 640 mL/L settling test and 3,000 mg/L MLSS to identify the high-SVI warning in an activated sludge case.
Check a 50 mL/g SVI from 180 mL/L settled volume in a compacting activated sludge sample.
Explore undefined finite solids age when both WAS and effluent TSS are entered as zero.
Separate carbon removal from nitrogen oxidation when 90% of a 45 mg/L TKN load is expected to nitrify.
F/M = (Q × BOD₅) / (V × MLVSS)Use influent load to the aeration stage and the volatile mixed-liquor inventory. With consistent volume and concentration units the result is per day.
MCRT = (V × MLSS + extra mass) / (QWAS × XWAS + Qeff × TSSₑ)The calculator estimates effluent flow as influent minus WAS. Include measured clarifier solids in extra inventory if using the whole-train basis. RAS stays within the inventory boundary.
SVI = 1,000 × SV₃₀ / MLSSUse 30-minute settled volume in mL/L and MLSS in mg/L. Compare time trends at the same test conditions.
AOR = f꜀ × load(BOD₅ removed) + 4.57 × load(N oxidized)The second term is optional. Use the fraction of incoming TKN expected to oxidize to nitrate. The carbon factor is empirical. This gross estimate excludes denitrification credit and oxygen transfer.
WEF 11 and EPA process-control guidance place F/M and MCRT in the context of plant operations. SVI below 70 or above 150 mL/g prompts review for atypical settling. Confirm actual settling, clarity and oxygen demand with samples and site data.
Return activated sludge moves solids from the secondary clarifier back to aeration. WAS and effluent solids cross the system boundary.
A 100% fraction assumes all reported TKN oxidizes to nitrate. Use measured or design nitrifiable nitrogen to account for unconverted organic nitrogen and assimilation.
WaterTreatLab / Current operating point
US customary units
For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.