WaterTreatLab

Chemical feed / Worked example

Coagulant Pump at 96% Capacity

Check liquid coagulant feed at 6 MGD, with a 25 mg/L active target and a 9.5 gph rated metering pump.

Inputs

Process & solution
mg/L
%
Mass percent (w/w)
Pump & inventory
gph
gal
gal

Results

US customary
Liquid feed
9.1055 gph 574.47 mL/min
Active chemical
1,251 lb/d 567.44 kg/d
Pump capacity used
95.847 %
Day-tank autonomy
1.8304 d
Chemical metering circuitLive diagram
Chemical metering circuitThe day-tank fill shows remaining stock after 24 hours from a full tank. Day-tank autonomy1.8304 dLiquid stock feed9.1055 gphMetering pumpProcess mainRequired pump output95.847 %10%90%
The day-tank fill shows remaining stock after 24 hours from a full tank.
Review the operating point
  • Above 90% of rated flow. Review capacity margin at operating backpressure.
Bulk-tank autonomy
16.016 d
Dose target
25 mg/L
Dose at rated flow
26.083 mg/L
Stock used per day
218.53 gal/d

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. A load of 1251 lb/day active at 48% strength and 1.43 SG needs 9.1055 gph stock.
  2. Divide by the 9.5 gph rating for 95.85% of capacity. The result triggers the 90% margin review.

More worked examples

Hypochlorite Feed at 2 MGD

Calculate active chemical pounds per day, metering pump flow and day-tank autonomy for a 2 MGD hypochlorite case.

Equations & conventions

Active mass rate
W = 8.34 × Qₘɢᴅ × D

Q is US million gallons per day, D is mg/L of active chemical and W is lb/day. The tool uses the EPA operator convention of 8.34 exactly.

Liquid feed rate
q = W / (24 × 8.34 × SG × w)

w is active mass fraction, for example 0.125 at 12.5% w/w. The result is US gal/h. Use the stock-specific SG and the same active chemical basis as the dose target.

Capacity and inventory
Setting = 100q / qᵣₐₜₑ𝒹, autonomy = Vᵤₛₐᵦₗₑ / (24q)

Pump setting is the equivalent share of rated flow. Calibrate stroke and speed at actual pressure. Use liquid inventory above the unusable heel and any reserved stock.

Planning basis

The 10% and 90% marks flag turndown and capacity margin for review. The pump’s calibrated performance curve governs the actual setting. Dose and residual have distinct meanings in treatment.

Questions

What drives the capacity warning for this coagulant example?

Rated pump capacity exceeds the calculation by about 0.39 gph. Verify that headroom at the actual injection pressure and flow range.