WaterTreatLab

Membrane separation / Worked example

72% Recovery from a Brackish Well

Work through a 100 gpm well-water RO train with 18 membrane elements, including 72% recovery, flux and concentrate TDS.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
72 %
Permeate flux
14.4 GFD 24.447 LMH
Concentrate TDS
6,359.1 mg/L
Feed osmotic pressure
22.147 psi 1.527 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed100 gpmPermeate72 gpm18 active elementsConcentrate28 gpmSystem recovery72 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
3.5714 ×
Concentrate flow
28 gpm
Permeate TDS
27 mg/L
Concentrate osmotic pressure
78.243 psi 5.3947 bar
Total active area
7,200 ft²
Flux review threshold
18 GFD 30.559 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Divide 72 gpm permeate by 100 gpm feed. Recovery is 72%, leaving 28 gpm as concentrate.
  2. Multiply 18 elements by 400 ft². The flux is 72 × 1,440 ÷ 7,200 = 14.4 GFD.
  3. At 98.5% rejection, the permeate carries 27 mg/L TDS. The salt balance gives about 6,359 mg/L in the concentrate.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

What are the three RO streams in the 72% well case?

The feed is 100 gpm, permeate is 72 gpm and concentrate is 28 gpm. The two outlet flows add to the feed.