WaterTreatLab

Membrane separation / Worked example

Filtered Reuse RO at 9.82 GFD

Calculate the low membrane flux and salt balance for a filtered municipal reuse train with 30 high-area elements.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
60 %
Permeate flux
9.8182 GFD 16.669 LMH
Concentrate TDS
2,332.3 mg/L
Feed osmotic pressure
11.689 psi 0.80592 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed150 gpmPermeate90 gpm30 active elementsConcentrate60 gpmSystem recovery60 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
2.5 ×
Concentrate flow
60 gpm
Permeate TDS
28.5 mg/L
Concentrate osmotic pressure
28.696 psi 1.9785 bar
Total active area
13,200 ft²
Flux review threshold
12 GFD 20.373 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. Divide 129,600 gal/day permeate by 13,200 ft² of active membrane for about 9.82 GFD.
  2. At 97% rejection, the permeate TDS is 28.5 mg/L. The 60 gpm concentrate is about 2,332 mg/L.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

How much area does the reuse train use for flux?

Thirty elements at 440 ft² give 13,200 ft² of active membrane area.