WaterTreatLab

Membrane separation / Worked example

RO with 90% Observed Salt Rejection

Compare ideal concentration factor with mass-balanced concentrate TDS when an 80 gpm RO feed has measurable salt passage.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
60 %
Permeate flux
12.343 GFD 20.955 LMH
Concentrate TDS
4,935 mg/L
Feed osmotic pressure
25.839 psi 1.7815 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed80 gpmPermeate48 gpm14 active elementsConcentrate32 gpmSystem recovery60 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
2.5 ×
Concentrate flow
32 gpm
Permeate TDS
210 mg/L
Concentrate osmotic pressure
60.721 psi 4.1865 bar
Total active area
5,600 ft²
Flux review threshold
18 GFD 30.559 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. The train recovers 60% of its feed, so ideal CF is 2.5.
  2. At 90% observed rejection, permeate is 210 mg/L. The full balance gives 4,935 mg/L concentrate compared with 5,250 mg/L for complete rejection.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

What does a 90% system rejection mean at 2,100 mg/L feed?

The simplified passage calculation assigns 10% of the feed concentration, or 210 mg/L, to the permeate.