RO Feed with Zero Permeate Flow

Trace the water and salt balance in a zero-permeate snapshot with 60 gpm entering the RO train.

Inputs

Membrane train
gpm
gpm
ft²
Feedwater
mg/L
%
°F

Results

US customary
Recovery
0 %
Permeate flux
0 GFD 0 LMH
Concentrate TDS
1,250 mg/L
Feed osmotic pressure
15.38 psi 1.0604 bar
RO pressure vesselLive diagram
RO pressure vesselFlow and dissolved-solids balance across the membrane train. Feed60 gpmPermeate0 gpm18 active elementsConcentrate60 gpmSystem recovery0 %0%75% review100%
Flow and dissolved-solids balance across the membrane train.
Concentration factor
1 ×
Concentrate flow
60 gpm
Permeate TDS
18.75 mg/L
Concentrate osmotic pressure
15.38 psi 1.0604 bar
Total active area
7,200 ft²
Flux review threshold
18 GFD 30.559 LMH

For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.

Worked solution

These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.

  1. A zero permeate flow yields zero recovery and flux.
  2. All 60 gpm and its dissolved solids go to the concentrate stream in this balance. The concentrate TDS equals the feed TDS of 1,250 mg/L.

More worked examples

Equations & conventions

Water balance
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)

Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.

Membrane flux
J = 1,440 × Qₚ / (Aₑ × N)

With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.

Salt balance
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸

Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.

Osmotic pressure
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77

This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.

Planning basis

The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.

Questions

Can I sample permeate TDS during this zero-flow case?

Permeate flow is zero, so the displayed passage concentration is hypothetical. There is no flowing permeate to sample.