72% Recovery from a Brackish Well
Work through a 100 gpm well-water RO train with 18 membrane elements, including 72% recovery, flux and concentrate TDS.
Membrane separation / Worked example
Compare ideal concentration factor with mass-balanced concentrate TDS when an 80 gpm RO feed has measurable salt passage.
For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.
These steps walk through the starting inputs in US customary units. Edit the calculator above to test a different operating point.
Work through a 100 gpm well-water RO train with 18 membrane elements, including 72% recovery, flux and concentrate TDS.
Evaluate a 200 gpm surface-water RO feed at 65% recovery and compare the 13 GFD permeate flux with the surface-water screen.
See how a 120 gpm RO feed at 85% recovery increases concentrate TDS and trips both system recovery and flux screens.
Calculate the low membrane flux and salt balance for a filtered municipal reuse train with 30 high-area elements.
Check a 15 gpm cold-water RO pilot with eight elements. Compare feed osmotic pressure and the surface-water flux screen.
Trace the water and salt balance in a zero-permeate snapshot with 60 gpm entering the RO train.
R = Qₚ / Q𝒻, Q𝒸 = Q𝒻 − Qₚ, CF = Q𝒻 / Q𝒸 = 1 / (1 − R)Use simultaneous feed and permeate flows at steady state. CF is the ideal concentration factor for completely rejected solute.
J = 1,440 × Qₚ / (Aₑ × N)With gpm and ft², J is gal/(ft²·d), or GFD. One GFD is approximately 1.698 LMH. Use the active area in the membrane datasheet.
Cₚ = C𝒻(1 − r), C𝒸 = (Q𝒻C𝒻 − QₚCₚ) / Q𝒸Enter system rejection as a percentage referenced to feed TDS. The concentrate TDS includes modeled salt passage.
π ≈ 2 × 0.0831446 × Tₖ × C / 58,442.77This gives bar with C in mg/L and assumes ideal NaCl-equivalent TDS at the entered water temperature. Ion speciation and activity change the real result.
The 75% system-recovery screen and 18/14/12 GFD well/surface/reuse screens are preliminary review triggers. DuPont Table 22 varies by pretreatment and feed SDI and lists separate element-level limits. AWWA M46 and the selected membrane projection provide design context.
The simplified passage calculation assigns 10% of the feed concentration, or 210 mg/L, to the permeate.
WaterTreatLab / RO with 90% Observed Salt Rejection
US customary units
For engineering planning. Operators must follow site-specific permits, chemical safety data sheets (SDS), manufacturer specifications, and certified regulatory sampling requirements.