WeibullMTBFLab · Engineering calculation
Humidity reversal in a connector test
A chamber is hotter than the use condition but at 50% RH, below the 70% use RH. The humidity term reduces the modeled acceleration.
Stress humidity is below use humidity.
Inputs
- Stress model
- Peck · temperature and humidity
- Activation energy Eₐ
- 0.62 eV
- Use temperature
- 40 °C
- Stress temperature
- 85 °C
- Use relative humidity
- 70 %
- Stress relative humidity
- 50 %
- Humidity exponent n
- 3
- Chamber time per device
- 240 h
- Test devices
- 30
- Confidence CL
- 0.9 0–1
Results
- Combined AF
- 6.536259 ×
- Field age
- 1,568.702 h
- Fleet exposure
- 47,061.06 device·h
- Upper FIT
- 48,927.6
- Temperature AF
- 17.93549 ×
- Humidity AF
- 0.3644315 ×
- Field age per device
- 0.1790756 yr
- Pooled field exposure
- 5.372268 device·yr
- Confidence CL
- 0.9
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 313.15 K and stress 358.15 K give 17.93549×.AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 0.3644315×.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 1,568.702 h per device and 47,061.06 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 48,927.6 FIT.
Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.