AEC-Q100-style Grade 1 HTOL
Explore 231 devices at a 150 °C chamber setting for 1,000 hours, a 75 °C use temperature and 0.8 eV for the selected failure mechanism.
Stress accelerates modeled exposure
Inputs
- Stress model
- Arrhenius · temperature
- Activation energy Eₐ
- 0.8 eV
- Use temperature
- 75 °C
- Stress temperature
- 150 °C
- Chamber time per device
- 1,000 h
- Test devices
- 231
- Confidence CL
- 0.95 0–1
Results
- Combined AF
- 112.8726 ×
- Field age
- 112,872.6 h
- Fleet exposure
- 26,073,580 device·h
- Upper FIT
- 114.8953
- Temperature AF
- 112.8726 ×
- Humidity AF
- 1 ×
- Field age per device
- 12.885 yr
- Pooled field exposure
- 2,976.436 device·yr
- Confidence CL
- 0.95
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 348.15 K and stress 423.15 K give 112.8726×.AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 112,872.6 h per device and 26,073,580 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 114.8953 FIT.
Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.