Automotive electronics case

AEC-Q100-style Grade 1 HTOL

Explore 231 devices at a 150 °C chamber setting for 1,000 hours, a 75 °C use temperature and 0.8 eV for the selected failure mechanism.

Inputs

eV
°C
°C
h
0–1
PassStress accelerates modeled exposure
Combined AF
112.873×
Field age
112,873h
Fleet exposure
2.607e7device·h
Upper FIT
114.895

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.21.182.5675105135164Chamber temperature (°C)TemperatureAF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
112.8726 ×
Humidity AF
1 ×
Field age per device
12.885 yr
Pooled field exposure
2,976.436 device·yr
Confidence CL
0.95

Change the activation energy to see how strongly an uncertain mechanism parameter changes the FIT bound. Conditions here are illustrative.

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 348.15 K and stress 423.15 K give 112.8726×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 112,872.6 h per device and 26,073,580 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 114.8953 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.