WeibullMTBFLab · Engineering calculation
Server PSU dry-heat exposure
A lab exposes 48 server power supplies for 500 hours at 95 °C. Estimate mechanism-specific equivalent field time at 50 °C.
Stress accelerates modeled exposure
Inputs
- Stress model
- Arrhenius · temperature
- Activation energy Eₐ
- 0.48 eV
- Use temperature
- 50 °C
- Stress temperature
- 95 °C
- Chamber time per device
- 500 h
- Test devices
- 48
- Confidence CL
- 0.95 0–1
Results
- Combined AF
- 8.223029 ×
- Field age
- 4,111.515 h
- Fleet exposure
- 197,352.7 device·h
- Upper FIT
- 15,179.59
- Temperature AF
- 8.223029 ×
- Humidity AF
- 1 ×
- Field age per device
- 0.469351 yr
- Pooled field exposure
- 22.52885 device·yr
- Confidence CL
- 0.95
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 323.15 K and stress 368.15 K give 8.223029×.AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 4,111.515 h per device and 197,352.7 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 15,179.59 FIT.
Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.