WeibullMTBFLab · Engineering calculation
Outdoor PV controller damp heat
Estimate equivalent exposure for 32 sealed controller boards tested at 85 °C and 85% RH, compared with 35 °C and 70% RH.
Stress accelerates modeled exposure
Inputs
- Stress model
- Peck · temperature and humidity
- Activation energy Eₐ
- 0.55 eV
- Use temperature
- 35 °C
- Stress temperature
- 85 °C
- Use relative humidity
- 70 %
- Stress relative humidity
- 85 %
- Humidity exponent n
- 2.3
- Chamber time per device
- 1,500 h
- Test devices
- 32
- Confidence CL
- 0.9 0–1
Results
- Combined AF
- 28.16618 ×
- Field age
- 42,249.27 h
- Fleet exposure
- 1,351,977 device·h
- Upper FIT
- 1,703.125
- Temperature AF
- 18.02146 ×
- Humidity AF
- 1.562925 ×
- Field age per device
- 4.822976 yr
- Pooled field exposure
- 154.3352 device·yr
- Confidence CL
- 0.9
AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 308.15 K and stress 358.15 K give 18.02146×.AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 1.562925×.AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 42,249.27 h per device and 1,351,977 pooled device-hours.FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 1,703.125 FIT.
Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.