Industrial electronics case

Humidity reversal in a connector test

A chamber is hotter than the use condition but at 50% RH, below the 70% use RH. The humidity term reduces the modeled acceleration.

Inputs

eV
°C
°C
%
%
h
0–1
FailStress humidity is below use humidity.
Combined AF
6.53626×
Field age
1,568.7h
Fleet exposure
47,061.1device·h
Upper FIT
48,927.6

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.6380.5721.784059.779.399Chamber temperature (°C)CombinedTemp.AF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
17.93549 ×
Humidity AF
0.3644315 ×
Field age per device
0.1790756 yr
Pooled field exposure
5.372268 device·yr
Confidence CL
0.9

Use the stress-direction check alongside the total multiplier. A combined multiplier above 1 can still contain a reversed humidity condition.

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 313.15 K and stress 358.15 K give 17.93549×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 0.3644315×.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 1,568.702 h per device and 47,061.06 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 48,927.6 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.

Method and sources