Power electronics case

Outdoor PV controller damp heat

Estimate equivalent exposure for 32 sealed controller boards tested at 85 °C and 85% RH, compared with 35 °C and 70% RH.

Inputs

eV
°C
°C
%
%
h
0–1
PassStress accelerates modeled exposure
Combined AF
28.1662×
Field age
42,249.3h
Fleet exposure
1,351,980device·h
Upper FIT
1,703.12

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.20.871.943556.377.799Chamber temperature (°C)CombinedTemp.AF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
18.02146 ×
Humidity AF
1.562925 ×
Field age per device
4.822976 yr
Pooled field exposure
154.3352 device·yr
Confidence CL
0.9

Use board-level temperature and RH estimates appropriate for the failure mechanism. Ambient conditions can differ from conditions inside the enclosure.

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 308.15 K and stress 358.15 K give 18.02146×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe relative-humidity ratio gives 1.562925×.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 42,249.27 h per device and 1,351,977 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 1,703.125 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.

Method and sources

Related examples