Hyperscale infrastructure case

Server PSU dry-heat exposure

A lab exposes 48 server power supplies for 500 hours at 95 °C. Estimate mechanism-specific equivalent field time at 50 °C.

Inputs

eV
°C
°C
h
0–1
PassStress accelerates modeled exposure
Combined AF
8.22303×
Field age
4,111.51h
Fleet exposure
197,353device·h
Upper FIT
15,179.6

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.20.5781.365069.789.3109Chamber temperature (°C)TemperatureAF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
8.223029 ×
Humidity AF
1 ×
Field age per device
0.469351 yr
Pooled field exposure
22.52885 device·yr
Confidence CL
0.95

The bound reflects the assumed dry-heat aging mechanism. Broader field failure modes need their own data.

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 323.15 K and stress 368.15 K give 8.223029×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 4,111.515 h per device and 197,352.7 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 15,179.59 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.

Method and sources