Tank engineering

Aquarium Heater Wattage & Chiller BTU Calculator

Estimate aquarium heater watts and chiller BTU/hr from room temperature, glass or acrylic, lids, evaporation, lighting and pump heat.

Inputs

View results
Tank and temperatures
US gal
in
in
in
in
°F
°F
°F
Evaporation and heat sources
US gal/day

Use observed refill water per day at the cold setting.

US gal/day

Use 0 when cooling credit is unknown.

W

Submerged equipment usually puts most of its watts into the water.

W
%
%
Heater capacity with reserve
160 W
Chiller capacity with reserve
500 BTU/hr
Cooling-equivalent horsepower
0.2 HP
Winter and summer heat balanceWinter need 127.62 watts and summer need 117.25 watts before reserve. Winter · lights offHeat loss159.6 WHeat gain32 WSummer · lights onHeat gain144 WHeat removed26.7 WCapacity includes 25% reserve.
Winter & summer heat balance

Calculation details

Winter water-to-air difference
15 °F
Summer air-to-water difference
8 °F
Winter panel and surface transfer
111.5 W
Winter evaporation losses
48.1 W
Summer evaporative cooling
26.7 W
Lighting heat reaching water
52.5 W
Estimated cold-start time
37.7 hr
  • Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.

Input measurements

Net water volume
90 US gal
Wall material
Glass
Inside length
48 in
Inside width
18 in
Water depth
22 in
Wall thickness
0.3937 in
Surface condition
Open top
Target water temperature
78 °F
Coldest room temperature
63 °F
Warmest room temperature
86 °F
Winter evaporation
0.45 US gal/day
Summer evaporation
0.25 US gal/day
Pump and equipment heat to water
32 W
Light electrical draw
150 W
Light draw reaching water as heat
35 %
Capacity reserve
25 %

Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.

How the calculation works

The model treats the tank as a rectangular water box. It applies heat transfer across the wetted sides and the top, with calm-air, glass or acrylic panel resistance and a lower lid coefficient. It leaves out an insulated bottom, direct sun, drafts and secondary tanks with different exposure.

Evaporation removes about 2.44 MJ per liter. Winter heater sizing subtracts submerged pump heat and assumes the lights are off. Warm air can offset winter evaporation when the room is above the water target. The warm case adds equipment and the estimated fraction of lighting heat reaching the water, then subtracts measured evaporative cooling.

Capacity includes the selected reserve. Chiller BTU/hr uses 3.412 BTU/hr per watt of cooling. Cooling-equivalent horsepower uses 745.7 W per mechanical horsepower. Match BTU/hr at actual design conditions to a manufacturer’s chart before choosing a model.

Frequently asked questions

Why can the same tank need more heat with the lid off?

An open top loses sensible heat to the room and can evaporate more water. Enter the evaporation you observe with each lid setup for a fair comparison.

Does a cooling-load horsepower estimate specify compressor horsepower?

The calculated figure expresses cooling capacity in mechanical horsepower units. The chiller’s compressor label describes the equipment. Select by rated cooling capacity in BTU/hr at the actual room and water temperatures.