Tank engineering
Aquarium Heater Wattage & Chiller BTU Calculator
Estimate aquarium heater watts and chiller BTU/hr from room temperature, glass or acrylic, lids, evaporation, lighting and pump heat.
Inputs
Results
Edit inputsAquarium Heater Wattage & Chiller BTU Calculator
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/aquarium-heater-wattage-chiller-btu-calculator/
- Heater capacity with reserve
- 160 W
- Chiller capacity with reserve
- 500 BTU/hr
- Cooling-equivalent horsepower
- 0.2 HP
Calculation details
- Winter water-to-air difference
- 15 °F
- Summer air-to-water difference
- 8 °F
- Winter panel and surface transfer
- 111.5 W
- Winter evaporation losses
- 48.1 W
- Summer evaporative cooling
- 26.7 W
- Lighting heat reaching water
- 52.5 W
- Estimated cold-start time
- 37.7 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 90 US gal
- Wall material
- Glass
- Inside length
- 48 in
- Inside width
- 18 in
- Water depth
- 22 in
- Wall thickness
- 0.3937 in
- Surface condition
- Open top
- Target water temperature
- 78 °F
- Coldest room temperature
- 63 °F
- Warmest room temperature
- 86 °F
- Winter evaporation
- 0.45 US gal/day
- Summer evaporation
- 0.25 US gal/day
- Pump and equipment heat to water
- 32 W
- Light electrical draw
- 150 W
- Light draw reaching water as heat
- 35 %
- Capacity reserve
- 25 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
How the calculation works
The model treats the tank as a rectangular water box. It applies heat transfer across the wetted sides and the top, with calm-air, glass or acrylic panel resistance and a lower lid coefficient. It leaves out an insulated bottom, direct sun, drafts and secondary tanks with different exposure.
Evaporation removes about 2.44 MJ per liter. Winter heater sizing subtracts submerged pump heat and assumes the lights are off. Warm air can offset winter evaporation when the room is above the water target. The warm case adds equipment and the estimated fraction of lighting heat reaching the water, then subtracts measured evaporative cooling.
Capacity includes the selected reserve. Chiller BTU/hr uses 3.412 BTU/hr per watt of cooling. Cooling-equivalent horsepower uses 745.7 W per mechanical horsepower. Match BTU/hr at actual design conditions to a manufacturer’s chart before choosing a model.
Frequently asked questions
Why can the same tank need more heat with the lid off?
An open top loses sensible heat to the room and can evaporate more water. Enter the evaporation you observe with each lid setup for a fair comparison.
Does a cooling-load horsepower estimate specify compressor horsepower?
The calculated figure expresses cooling capacity in mechanical horsepower units. The chiller’s compressor label describes the equipment. Select by rated cooling capacity in BTU/hr at the actual room and water temperatures.