Worked example
20-Gallon Lidded Acrylic Aquarium Heater for a 10 °F Rise
A 20-gallon lidded aquarium has a 24 × 12 in plan and 15 in of water. It uses 6 mm acrylic, a 68 °F winter room and 0.06 gallon per day of evaporation.
See the worked calculationInputs
Results
Edit inputs20-Gallon Lidded Acrylic Aquarium Heater for a 10 °F Rise
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/20-gallon-lidded-acrylic-tank-heater-10-degree-rise/
- Heater capacity with reserve
- 28 W
- Chiller capacity with reserve
- 125 BTU/hr
- Cooling-equivalent horsepower
- 0.05 HP
Calculation details
- Winter water-to-air difference
- 10 °F
- Summer air-to-water difference
- 8 °F
- Winter panel and surface transfer
- 20.8 W
- Winter evaporation losses
- 6.4 W
- Summer evaporative cooling
- 0 W
- Lighting heat reaching water
- 5.5 W
- Estimated cold-start time
- 29.2 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 20 US gal
- Wall material
- Acrylic
- Inside length
- 24 in
- Inside width
- 12 in
- Water depth
- 15 in
- Wall thickness
- 0.23622 in
- Surface condition
- Lidded
- Target water temperature
- 78 °F
- Coldest room temperature
- 68 °F
- Warmest room temperature
- 86 °F
- Winter evaporation
- 0.06 US gal/day
- Summer evaporation
- 0 US gal/day
- Pump and equipment heat to water
- 6 W
- Light electrical draw
- 22 W
- Light draw reaching water as heat
- 25 %
- Capacity reserve
- 30 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate heat transfer through the wetted area
(0.697 m² × 4.84 W/m²/K) + (0.186 m² × 2 W/m²/K) = 3.74 W/K
The acrylic wall resistance includes the selected 6 mm thickness. The modeled top is lidded.
Balance the cold-night heat
max(0, 20.79 W + 6.41 W − 6 W) × 1.3 = 27.6 W
At a 10 °F rise, evaporation adds 0.227 L/day × 28.24 W per L/day of loss.
Balance the summer heat
max(0, 16.64 W + 6 W + 5.5 W − 0 W) × 1.3 = 36.6 W cooling
Multiply by 3.412 to get 124.8 BTU/hr. The thermal equivalent is 0.05 HP.
Frequently asked questions
Does a lid eliminate heat loss from a 20-gallon tank?
A lid can reduce surface transfer and evaporation. The wetted sides still lose heat, and air gaps or openings can let more air and moisture escape.
Why enter acrylic thickness on a small covered aquarium?
Thickness changes the wall’s thermal resistance. Air movement and evaporation can still have a bigger effect on the result.