Worked example

40-Gallon Breeder Heater Load with an Open Top or Lid

A 40-gallon breeder at 76 °F sits in a 64 °F room. The open setup evaporates 0.38 gallon per day. Switch to lidded and enter the new measured evaporation to compare.

See the worked calculation

Inputs

View results
Tank and temperatures
US gal
in
in
in
in
°F
°F
°F
Evaporation and heat sources
US gal/day

Use observed refill water per day at the cold setting.

US gal/day

Use 0 when cooling credit is unknown.

W

Submerged equipment usually puts most of its watts into the water.

W
%
%
Winter evaporation losses
40.6 W
Heater capacity with reserve
95 W
Chiller capacity with reserve
195 BTU/hr
Winter and summer heat balanceWinter need 76.18 watts and summer need 45.7 watts before reserve. Winter · lights offHeat loss92.2 WHeat gain16 WSummer · lights onHeat gain67.1 WHeat removed21.4 WCapacity includes 25% reserve.
Winter & summer heat balance

Calculation details

Cooling-equivalent horsepower
0.08 HP
Winter water-to-air difference
12 °F
Summer air-to-water difference
7 °F
Winter panel and surface transfer
51.6 W
Summer evaporative cooling
21.4 W
Lighting heat reaching water
21 W
Estimated cold-start time
26.2 hr
  • Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.

Input measurements

Net water volume
40 US gal
Wall material
Glass
Inside length
36 in
Inside width
18 in
Water depth
14 in
Wall thickness
0.3937 in
Surface condition
Open top
Target water temperature
76 °F
Coldest room temperature
64 °F
Warmest room temperature
83 °F
Winter evaporation
0.38 US gal/day
Summer evaporation
0.2 US gal/day
Pump and equipment heat to water
16 W
Light electrical draw
60 W
Light draw reaching water as heat
35 %
Capacity reserve
25 %

Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate heat transfer through the wetted area

    (0.975 m² × 5.36 W/m²/K) + (0.418 m² × 6 W/m²/K) = 7.73 W/K

    The glass wall resistance includes the selected 10 mm thickness. The modeled top is open.

  2. Balance the cold-night heat

    max(0, 51.56 W + 40.62 W − 16 W) × 1.25 = 95.2 W

    At a 12 °F rise, evaporation adds 1.438 L/day × 28.24 W per L/day of loss.

  3. Balance the summer heat

    max(0, 30.08 W + 16 W + 21 W − 21.38 W) × 1.25 = 57.1 W cooling

    Multiply by 3.412 to get 194.9 BTU/hr. The thermal equivalent is 0.08 HP.

Frequently asked questions

Which two settings do I edit for a lid comparison on a breeder?

Change the surface condition and enter the evaporation you measure with that lid. Leave tank dimensions and ambient temperatures the same.

Can a fan change the breeder’s apparent heat loss?

A fan changes local air movement and evaporation. Measure summer and winter losses separately if the fan only runs in hot weather.