Worked example
40-Gallon Breeder Heater Load with an Open Top or Lid
A 40-gallon breeder at 76 °F sits in a 64 °F room. The open setup evaporates 0.38 gallon per day. Switch to lidded and enter the new measured evaporation to compare.
See the worked calculationInputs
Results
Edit inputs40-Gallon Breeder Heater Load with an Open Top or Lid
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/40-gallon-breeder-lid-vs-open-heat-loss/
- Winter evaporation losses
- 40.6 W
- Heater capacity with reserve
- 95 W
- Chiller capacity with reserve
- 195 BTU/hr
Calculation details
- Cooling-equivalent horsepower
- 0.08 HP
- Winter water-to-air difference
- 12 °F
- Summer air-to-water difference
- 7 °F
- Winter panel and surface transfer
- 51.6 W
- Summer evaporative cooling
- 21.4 W
- Lighting heat reaching water
- 21 W
- Estimated cold-start time
- 26.2 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 40 US gal
- Wall material
- Glass
- Inside length
- 36 in
- Inside width
- 18 in
- Water depth
- 14 in
- Wall thickness
- 0.3937 in
- Surface condition
- Open top
- Target water temperature
- 76 °F
- Coldest room temperature
- 64 °F
- Warmest room temperature
- 83 °F
- Winter evaporation
- 0.38 US gal/day
- Summer evaporation
- 0.2 US gal/day
- Pump and equipment heat to water
- 16 W
- Light electrical draw
- 60 W
- Light draw reaching water as heat
- 35 %
- Capacity reserve
- 25 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate heat transfer through the wetted area
(0.975 m² × 5.36 W/m²/K) + (0.418 m² × 6 W/m²/K) = 7.73 W/K
The glass wall resistance includes the selected 10 mm thickness. The modeled top is open.
Balance the cold-night heat
max(0, 51.56 W + 40.62 W − 16 W) × 1.25 = 95.2 W
At a 12 °F rise, evaporation adds 1.438 L/day × 28.24 W per L/day of loss.
Balance the summer heat
max(0, 30.08 W + 16 W + 21 W − 21.38 W) × 1.25 = 57.1 W cooling
Multiply by 3.412 to get 194.9 BTU/hr. The thermal equivalent is 0.08 HP.
Frequently asked questions
Which two settings do I edit for a lid comparison on a breeder?
Change the surface condition and enter the evaporation you measure with that lid. Leave tank dimensions and ambient temperatures the same.
Can a fan change the breeder’s apparent heat loss?
A fan changes local air movement and evaporation. Measure summer and winter losses separately if the fan only runs in hot weather.