Worked example
180-Gallon Acrylic Aquarium Chiller with Pump Heat
This lidded 180-gallon acrylic system can see a room temperature of 85 °F. The pumps contribute 110 W to the water and lighting contributes another 55 W in the warm case.
See the worked calculationInputs
Results
Edit inputs180-Gallon Acrylic Aquarium Chiller with Pump Heat
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/180-gallon-acrylic-aquarium-chiller-pump-heat/
- Cooling-equivalent horsepower
- 0.36 HP
- Heater capacity with reserve
- 0 W
- Chiller capacity with reserve
- 918 BTU/hr
Calculation details
- Winter water-to-air difference
- 11 °F
- Summer air-to-water difference
- 7 °F
- Winter panel and surface transfer
- 78.9 W
- Winter evaporation losses
- 12.8 W
- Summer evaporative cooling
- 0 W
- Lighting heat reaching water
- 55 W
- Estimated cold-start time
- 83.9 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 180 US gal
- Wall material
- Acrylic
- Inside length
- 72 in
- Inside width
- 24 in
- Water depth
- 23 in
- Wall thickness
- 0.70866 in
- Surface condition
- Lidded
- Target water temperature
- 78 °F
- Coldest room temperature
- 67 °F
- Warmest room temperature
- 85 °F
- Winter evaporation
- 0.12 US gal/day
- Summer evaporation
- 0 US gal/day
- Pump and equipment heat to water
- 110 W
- Light electrical draw
- 220 W
- Light draw reaching water as heat
- 25 %
- Capacity reserve
- 25 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate heat transfer through the wetted area
(2.849 m² × 3.75 W/m²/K) + (1.115 m² × 2 W/m²/K) = 12.91 W/K
The acrylic wall resistance includes the selected 18 mm thickness. The modeled top is lidded.
Balance the summer heat
max(0, 50.22 W + 110 W + 55 W − 0 W) × 1.25 = 269 W cooling
Multiply by 3.412 to get 917.9 BTU/hr. The thermal equivalent is 0.36 HP.
Balance the cold-night heat
max(0, 78.92 W + 12.83 W − 110 W) × 1.25 = 0 W
At a 11 °F rise, evaporation adds 0.454 L/day × 28.24 W per L/day of loss.
Frequently asked questions
Why does the 180-gallon chiller model use pump heat even under a lid?
Submerged pumps deposit energy directly into the water. The lid changes heat exchange with air but leaves the submerged electrical load in place.
Does cooling-equivalent HP define the electricity used by this chiller?
No. Cooling capacity describes heat removed per time. Electrical draw depends on the chiller’s design and efficiency at those operating conditions.