Worked example
55-Gallon Aquarium Heater Capacity for a 58 °F Room
A long 55-gallon tank stays at 76 °F in a room that can fall to 58 °F. The lid is fitted, and the open filter section still accounts for 0.16 gallon per day of water loss.
See the worked calculationInputs
Results
Edit inputs55-Gallon Aquarium Heater Capacity for a 58 °F Room
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/55-gallon-aquarium-dual-heater-cold-room-sizing/
- Heater capacity with reserve
- 129 W
- Chiller capacity with reserve
- 291 BTU/hr
- Cooling-equivalent horsepower
- 0.11 HP
Calculation details
- Winter water-to-air difference
- 18 °F
- Summer air-to-water difference
- 6 °F
- Winter panel and surface transfer
- 90.4 W
- Winter evaporation losses
- 17.1 W
- Summer evaporative cooling
- 0 W
- Lighting heat reaching water
- 21 W
- Estimated cold-start time
- 30.8 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 55 US gal
- Wall material
- Glass
- Inside length
- 48 in
- Inside width
- 12 in
- Water depth
- 20 in
- Wall thickness
- 0.3937 in
- Surface condition
- Lidded
- Target water temperature
- 76 °F
- Coldest room temperature
- 58 °F
- Warmest room temperature
- 82 °F
- Winter evaporation
- 0.16 US gal/day
- Summer evaporation
- 0 US gal/day
- Pump and equipment heat to water
- 12 W
- Light electrical draw
- 70 W
- Light draw reaching water as heat
- 30 %
- Capacity reserve
- 35 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate heat transfer through the wetted area
(1.548 m² × 5.36 W/m²/K) + (0.372 m² × 2 W/m²/K) = 9.04 W/K
The glass wall resistance includes the selected 10 mm thickness. The modeled top is lidded.
Balance the cold-night heat
max(0, 90.38 W + 17.1 W − 12 W) × 1.35 = 128.9 W
At a 18 °F rise, evaporation adds 0.606 L/day × 28.24 W per L/day of loss.
Balance the summer heat
max(0, 30.13 W + 12 W + 21 W − 0 W) × 1.35 = 85.2 W cooling
Multiply by 3.412 to get 290.8 BTU/hr. The thermal equivalent is 0.11 HP.
Frequently asked questions
Do two 75 W heaters give a 55-gallon tank 150 W of backup?
Together they give 150 W when both run. If either fails, only the surviving 75 W remains, assuming independent controls and power.
Why measure a 55-gallon cold room at night?
The coldest room period can coincide with lights off and windows or doors closed. Measure near the aquarium so the estimate reflects its actual exposure.