Worked example

55-Gallon Aquarium Heater Capacity for a 58 °F Room

A long 55-gallon tank stays at 76 °F in a room that can fall to 58 °F. The lid is fitted, and the open filter section still accounts for 0.16 gallon per day of water loss.

See the worked calculation

Inputs

View results
Tank and temperatures
US gal
in
in
in
in
°F
°F
°F
Evaporation and heat sources
US gal/day

Use observed refill water per day at the cold setting.

US gal/day

Use 0 when cooling credit is unknown.

W

Submerged equipment usually puts most of its watts into the water.

W
%
%
Heater capacity with reserve
129 W
Chiller capacity with reserve
291 BTU/hr
Cooling-equivalent horsepower
0.11 HP
Winter and summer heat balanceWinter need 95.49 watts and summer need 63.13 watts before reserve. Winter · lights offHeat loss107.5 WHeat gain12 WSummer · lights onHeat gain63.1 WHeat removed0 WCapacity includes 35% reserve.
Winter & summer heat balance

Calculation details

Winter water-to-air difference
18 °F
Summer air-to-water difference
6 °F
Winter panel and surface transfer
90.4 W
Winter evaporation losses
17.1 W
Summer evaporative cooling
0 W
Lighting heat reaching water
21 W
Estimated cold-start time
30.8 hr
  • Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.

Input measurements

Net water volume
55 US gal
Wall material
Glass
Inside length
48 in
Inside width
12 in
Water depth
20 in
Wall thickness
0.3937 in
Surface condition
Lidded
Target water temperature
76 °F
Coldest room temperature
58 °F
Warmest room temperature
82 °F
Winter evaporation
0.16 US gal/day
Summer evaporation
0 US gal/day
Pump and equipment heat to water
12 W
Light electrical draw
70 W
Light draw reaching water as heat
30 %
Capacity reserve
35 %

Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate heat transfer through the wetted area

    (1.548 m² × 5.36 W/m²/K) + (0.372 m² × 2 W/m²/K) = 9.04 W/K

    The glass wall resistance includes the selected 10 mm thickness. The modeled top is lidded.

  2. Balance the cold-night heat

    max(0, 90.38 W + 17.1 W − 12 W) × 1.35 = 128.9 W

    At a 18 °F rise, evaporation adds 0.606 L/day × 28.24 W per L/day of loss.

  3. Balance the summer heat

    max(0, 30.13 W + 12 W + 21 W − 0 W) × 1.35 = 85.2 W cooling

    Multiply by 3.412 to get 290.8 BTU/hr. The thermal equivalent is 0.11 HP.

Frequently asked questions

Do two 75 W heaters give a 55-gallon tank 150 W of backup?

Together they give 150 W when both run. If either fails, only the surviving 75 W remains, assuming independent controls and power.

Why measure a 55-gallon cold room at night?

The coldest room period can coincide with lights off and windows or doors closed. Measure near the aquarium so the estimate reflects its actual exposure.