Worked example

90-Gallon Reef Heater Wattage for a 15 °F Rise

Hold a 90-gallon reef at 78 °F when the room drops to 63 °F. This open aquarium loses 0.45 US gallons to evaporation per day and receives 32 W of pump heat.

See the worked calculation

Inputs

View results
Tank and temperatures
US gal
in
in
in
in
°F
°F
°F
Evaporation and heat sources
US gal/day

Use observed refill water per day at the cold setting.

US gal/day

Use 0 when cooling credit is unknown.

W

Submerged equipment usually puts most of its watts into the water.

W
%
%
Heater capacity with reserve
160 W
Chiller capacity with reserve
500 BTU/hr
Cooling-equivalent horsepower
0.2 HP
Winter and summer heat balanceWinter need 127.62 watts and summer need 117.25 watts before reserve. Winter · lights offHeat loss159.6 WHeat gain32 WSummer · lights onHeat gain144 WHeat removed26.7 WCapacity includes 25% reserve.
Winter & summer heat balance

Calculation details

Winter water-to-air difference
15 °F
Summer air-to-water difference
8 °F
Winter panel and surface transfer
111.5 W
Winter evaporation losses
48.1 W
Summer evaporative cooling
26.7 W
Lighting heat reaching water
52.5 W
Estimated cold-start time
37.7 hr
  • Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.

Input measurements

Net water volume
90 US gal
Wall material
Glass
Inside length
48 in
Inside width
18 in
Water depth
22 in
Wall thickness
0.3937 in
Surface condition
Open top
Target water temperature
78 °F
Coldest room temperature
63 °F
Warmest room temperature
86 °F
Winter evaporation
0.45 US gal/day
Summer evaporation
0.25 US gal/day
Pump and equipment heat to water
32 W
Light electrical draw
150 W
Light draw reaching water as heat
35 %
Capacity reserve
25 %

Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate heat transfer through the wetted area

    (1.874 m² × 5.36 W/m²/K) + (0.557 m² × 6 W/m²/K) = 13.38 W/K

    The glass wall resistance includes the selected 10 mm thickness. The modeled top is open.

  2. Balance the cold-night heat

    max(0, 111.51 W + 48.11 W − 32 W) × 1.25 = 159.5 W

    At a 15 °F rise, evaporation adds 1.703 L/day × 28.24 W per L/day of loss.

  3. Balance the summer heat

    max(0, 59.47 W + 32 W + 52.5 W − 26.73 W) × 1.25 = 146.6 W cooling

    Multiply by 3.412 to get 500.1 BTU/hr. The thermal equivalent is 0.2 HP.

Frequently asked questions

Which temperature difference matters for the 90-gallon heater?

Use the target water temperature minus the coldest room temperature. This example uses 15 °F, which is 8.33 °C of temperature difference.

Should I count reef lighting in the 90-gallon winter heater calculation?

This example assumes the coldest case happens after the lights go out. The cold heat balance includes the pump watts that remain in the water.