Worked example
90-Gallon Reef Heater Wattage for a 15 °F Rise
Hold a 90-gallon reef at 78 °F when the room drops to 63 °F. This open aquarium loses 0.45 US gallons to evaporation per day and receives 32 W of pump heat.
See the worked calculationInputs
Results
Edit inputs90-Gallon Reef Heater Wattage for a 15 °F Rise
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/90-gallon-reef-heater-wattage-15-degree-rise/
- Heater capacity with reserve
- 160 W
- Chiller capacity with reserve
- 500 BTU/hr
- Cooling-equivalent horsepower
- 0.2 HP
Calculation details
- Winter water-to-air difference
- 15 °F
- Summer air-to-water difference
- 8 °F
- Winter panel and surface transfer
- 111.5 W
- Winter evaporation losses
- 48.1 W
- Summer evaporative cooling
- 26.7 W
- Lighting heat reaching water
- 52.5 W
- Estimated cold-start time
- 37.7 hr
- Match the BTU/hr capacity at your room temperature and selected water temperature to the chiller’s performance chart.
Input measurements
- Net water volume
- 90 US gal
- Wall material
- Glass
- Inside length
- 48 in
- Inside width
- 18 in
- Water depth
- 22 in
- Wall thickness
- 0.3937 in
- Surface condition
- Open top
- Target water temperature
- 78 °F
- Coldest room temperature
- 63 °F
- Warmest room temperature
- 86 °F
- Winter evaporation
- 0.45 US gal/day
- Summer evaporation
- 0.25 US gal/day
- Pump and equipment heat to water
- 32 W
- Light electrical draw
- 150 W
- Light draw reaching water as heat
- 35 %
- Capacity reserve
- 25 %
Check water temperature with an independent thermometer and verify heater and chiller output in your room before relying on them with livestock.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate heat transfer through the wetted area
(1.874 m² × 5.36 W/m²/K) + (0.557 m² × 6 W/m²/K) = 13.38 W/K
The glass wall resistance includes the selected 10 mm thickness. The modeled top is open.
Balance the cold-night heat
max(0, 111.51 W + 48.11 W − 32 W) × 1.25 = 159.5 W
At a 15 °F rise, evaporation adds 1.703 L/day × 28.24 W per L/day of loss.
Balance the summer heat
max(0, 59.47 W + 32 W + 52.5 W − 26.73 W) × 1.25 = 146.6 W cooling
Multiply by 3.412 to get 500.1 BTU/hr. The thermal equivalent is 0.2 HP.
Frequently asked questions
Which temperature difference matters for the 90-gallon heater?
Use the target water temperature minus the coldest room temperature. This example uses 15 °F, which is 8.33 °C of temperature difference.
Should I count reef lighting in the 90-gallon winter heater calculation?
This example assumes the coldest case happens after the lights go out. The cold heat balance includes the pump watts that remain in the water.