Worked example

10 × 15 × 3 ft Koi Pond Liner Size and Waterfall GPH

A rectangular koi pond is 15 ft long, 10 ft wide and 3 ft deep. Leave 1.5 ft on each edge and use 150 GPH per inch for an 18 in spillway.

See the worked calculation

Inputs

View results
Pond and liner
ft
ft
ft

Use an area-weighted average where there are shallow shelves.

ft

Measure from the liner crest to the deepest point.

ft

Use enough material for your edge, anchoring and folds.

Waterfall and circulation
in

Enter 0 if there is no waterfall.

US gal/h/in

Use the spillway’s rated flow for the sheet thickness you want.

×
ft
ft

Include pipe, valves and filter loss at the target flow.

UV clarifier
W/1,000 US gal

Match koi capacity and allowable flow on a manufacturer’s chart.

Minimum sheet length
24 ft
Estimated pond volume
3,366 US gal
Single-loop pump flow at head
3,366 US gal/h
Pond profile, EPDM sheet and overlapEstimated pond volume 3,366 US gal. Minimum sheet 24 ft by 19 ft. EPDM liner follows the excavation Max liner depth3 ftPer-edge overlap1.5 ftWater volume3,366 US galMinimum sheet24 ft × 19 ft
Pond section & liner allowance

Calculation details

Planning UV clarifier capacity
45.9 W
Minimum sheet width
19 ft
Waterfall flow alone
2,700 US gal/h
Circulation flow alone
3,366 US gal/h
Estimated total dynamic head
6 ft
  • Check the finished excavation with a rope or tape before ordering a liner.
  • Match the pump curve at total head and the UV model’s koi volume and flow ratings.

Input measurements

Pond plan
Rectangular
Maximum length
15 ft
Maximum width
10 ft
Average water depth
3 ft
Maximum liner depth
3 ft
Extra liner per edge
1.5 ft
Spillway width
18 in
Flow per unit of spillway width
150 US gal/h/in
Circulation target per hour
1 ×
Static lift to discharge
4 ft
Friction head allowance
2 ft
Planning UV power density
13.62748 W/1,000 US gal

Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate pond volume from the water plan

    15 ft × 10 ft × 1 × 3 ft → 3,366 US gal

    The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.

  2. Add liner depth and overlap to each direction

    2 × (3 ft + 1.5 ft) per dimension → 24 ft × 19 ft

    Use maximum depth and the full bounding dimensions for the sheet.

  3. Compare waterfall and turnover demand

    18 in × 150 US gal/h/in = 2,700 US gal/h; circulation = 3,366 US gal × 1/h → 3,366 US gal/h

    Use the larger flow on a single loop. Select at 6 ft total head.

  4. Estimate UV clarifier watts

    12.743 kL × 3.6 W/kL = 45.87 W

    Compare actual koi volume and allowable flow against a manufacturer chart.

Frequently asked questions

Why does the 10 × 15 ft pond need a 24 × 19 ft sheet?

Each direction adds two 3 ft depth allowances and two 1.5 ft edge overlaps. That is 9 ft beyond the pond’s length and width.

Does the 18-inch waterfall require a separate 2,700 GPH pump?

A single return can meet both needs if all circulation goes over the fall. In this example, compare the 2,700 GPH waterfall target with the circulation target and use the higher at head.