Worked example
10 × 15 × 3 ft Koi Pond Liner Size and Waterfall GPH
A rectangular koi pond is 15 ft long, 10 ft wide and 3 ft deep. Leave 1.5 ft on each edge and use 150 GPH per inch for an 18 in spillway.
See the worked calculationInputs
Results
Edit inputs10 × 15 × 3 ft Koi Pond Liner Size and Waterfall GPH
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/10x15x3-foot-koi-pond-liner-waterfall-gph/
- Minimum sheet length
- 24 ft
- Estimated pond volume
- 3,366 US gal
- Single-loop pump flow at head
- 3,366 US gal/h
Calculation details
- Planning UV clarifier capacity
- 45.9 W
- Minimum sheet width
- 19 ft
- Waterfall flow alone
- 2,700 US gal/h
- Circulation flow alone
- 3,366 US gal/h
- Estimated total dynamic head
- 6 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Rectangular
- Maximum length
- 15 ft
- Maximum width
- 10 ft
- Average water depth
- 3 ft
- Maximum liner depth
- 3 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 18 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1 ×
- Static lift to discharge
- 4 ft
- Friction head allowance
- 2 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate pond volume from the water plan
15 ft × 10 ft × 1 × 3 ft → 3,366 US gal
The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.
Add liner depth and overlap to each direction
2 × (3 ft + 1.5 ft) per dimension → 24 ft × 19 ft
Use maximum depth and the full bounding dimensions for the sheet.
Compare waterfall and turnover demand
18 in × 150 US gal/h/in = 2,700 US gal/h; circulation = 3,366 US gal × 1/h → 3,366 US gal/h
Use the larger flow on a single loop. Select at 6 ft total head.
Estimate UV clarifier watts
12.743 kL × 3.6 W/kL = 45.87 W
Compare actual koi volume and allowable flow against a manufacturer chart.
Frequently asked questions
Why does the 10 × 15 ft pond need a 24 × 19 ft sheet?
Each direction adds two 3 ft depth allowances and two 1.5 ft edge overlaps. That is 9 ft beyond the pond’s length and width.
Does the 18-inch waterfall require a separate 2,700 GPH pump?
A single return can meet both needs if all circulation goes over the fall. In this example, compare the 2,700 GPH waterfall target with the circulation target and use the higher at head.