Worked example
4,000-Gallon Koi Pond Pump Flow at 8 ft of Head
A 20 × 12 ft rectangular pond has a 2.25 ft average depth and 3.5 ft maximum. The setup aims for 1.25 turnovers per hour and adds 3 ft of friction to 5 ft of lift.
See the worked calculationInputs
Results
Edit inputs4,000-Gallon Koi Pond Pump Flow at 8 ft of Head
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/4000-gallon-koi-pond-pump-turnover-head/
- Single-loop pump flow at head
- 5,049 US gal/h
- Estimated pond volume
- 4,039 US gal
- Planning UV clarifier capacity
- 55 W
Calculation details
- Minimum sheet length
- 30 ft
- Minimum sheet width
- 22 ft
- Waterfall flow alone
- 3,600 US gal/h
- Circulation flow alone
- 5,049 US gal/h
- Estimated total dynamic head
- 8 ft
- Check the finished excavation with a rope or tape before ordering a liner.
- Match the pump curve at total head and the UV model’s koi volume and flow ratings.
Input measurements
- Pond plan
- Rectangular
- Maximum length
- 20 ft
- Maximum width
- 12 ft
- Average water depth
- 2.25 ft
- Maximum liner depth
- 3.5 ft
- Extra liner per edge
- 1.5 ft
- Spillway width
- 24 in
- Flow per unit of spillway width
- 150 US gal/h/in
- Circulation target per hour
- 1.25 ×
- Static lift to discharge
- 5 ft
- Friction head allowance
- 3 ft
- Planning UV power density
- 13.62748 W/1,000 US gal
Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Estimate pond volume from the water plan
20 ft × 12 ft × 1 × 2.25 ft → 4,039 US gal
The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.
Add liner depth and overlap to each direction
2 × (3.5 ft + 1.5 ft) per dimension → 30 ft × 22 ft
Use maximum depth and the full bounding dimensions for the sheet.
Compare waterfall and turnover demand
24 in × 150 US gal/h/in = 3,600 US gal/h; circulation = 4,039 US gal × 1.25/h → 5,049 US gal/h
Use the larger flow on a single loop. Select at 8 ft total head.
Estimate UV clarifier watts
15.291 kL × 3.6 W/kL = 55.05 W
Compare actual koi volume and allowable flow against a manufacturer chart.
Frequently asked questions
Can a pump labeled 5,000 GPH deliver turnover for this 4,000-gallon pond?
Read the flow at 8 ft on its pump curve. A headline number may describe zero head, where the pump delivers more flow than in this circuit.
Should I keep the 3 ft friction allowance if I change the return pipe?
Recompute friction at the desired flow if the pipe diameter, length or filter changes. The allowance is a planning input.