Worked example

4,000-Gallon Koi Pond Pump Flow at 8 ft of Head

A 20 × 12 ft rectangular pond has a 2.25 ft average depth and 3.5 ft maximum. The setup aims for 1.25 turnovers per hour and adds 3 ft of friction to 5 ft of lift.

See the worked calculation

Inputs

View results
Pond and liner
ft
ft
ft

Use an area-weighted average where there are shallow shelves.

ft

Measure from the liner crest to the deepest point.

ft

Use enough material for your edge, anchoring and folds.

Waterfall and circulation
in

Enter 0 if there is no waterfall.

US gal/h/in

Use the spillway’s rated flow for the sheet thickness you want.

×
ft
ft

Include pipe, valves and filter loss at the target flow.

UV clarifier
W/1,000 US gal

Match koi capacity and allowable flow on a manufacturer’s chart.

Single-loop pump flow at head
5,049 US gal/h
Estimated pond volume
4,039 US gal
Planning UV clarifier capacity
55 W
Pond profile, EPDM sheet and overlapEstimated pond volume 4,039 US gal. Minimum sheet 30 ft by 22 ft. EPDM liner follows the excavation Max liner depth3.5 ftPer-edge overlap1.5 ftWater volume4,039 US galMinimum sheet30 ft × 22 ft
Pond section & liner allowance

Calculation details

Minimum sheet length
30 ft
Minimum sheet width
22 ft
Waterfall flow alone
3,600 US gal/h
Circulation flow alone
5,049 US gal/h
Estimated total dynamic head
8 ft
  • Check the finished excavation with a rope or tape before ordering a liner.
  • Match the pump curve at total head and the UV model’s koi volume and flow ratings.

Input measurements

Pond plan
Rectangular
Maximum length
20 ft
Maximum width
12 ft
Average water depth
2.25 ft
Maximum liner depth
3.5 ft
Extra liner per edge
1.5 ft
Spillway width
24 in
Flow per unit of spillway width
150 US gal/h/in
Circulation target per hour
1.25 ×
Static lift to discharge
5 ft
Friction head allowance
3 ft
Planning UV power density
13.62748 W/1,000 US gal

Meter the actual fill and test pH, ammonia, nitrite and dissolved oxygen before stocking. Check the pump and UV ratings for your stock load and install electrical equipment according to its manual.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Estimate pond volume from the water plan

    20 ft × 12 ft × 1 × 2.25 ft → 4,039 US gal

    The shape factor applies to the water footprint. Use area-weighted water depth and convert the resulting cubic volume to gallons or liters.

  2. Add liner depth and overlap to each direction

    2 × (3.5 ft + 1.5 ft) per dimension → 30 ft × 22 ft

    Use maximum depth and the full bounding dimensions for the sheet.

  3. Compare waterfall and turnover demand

    24 in × 150 US gal/h/in = 3,600 US gal/h; circulation = 4,039 US gal × 1.25/h → 5,049 US gal/h

    Use the larger flow on a single loop. Select at 8 ft total head.

  4. Estimate UV clarifier watts

    15.291 kL × 3.6 W/kL = 55.05 W

    Compare actual koi volume and allowable flow against a manufacturer chart.

Frequently asked questions

Can a pump labeled 5,000 GPH deliver turnover for this 4,000-gallon pond?

Read the flow at 8 ft on its pump curve. A headline number may describe zero head, where the pump delivers more flow than in this circuit.

Should I keep the 3 ft friction allowance if I change the return pipe?

Recompute friction at the desired flow if the pipe diameter, length or filter changes. The allowance is a planning input.